13 input validation and invalid items – MoTeC M1 Tune User Manual User Manual
Page 60
User Manual
USING M1 TUNE
Printed documents are not controlled
Page 59
11.13 INPUT VALIDATION AND INVALID ITEMS
When a Package is created, parameters and tables are normally set up with input validation.
Input validation sets high and low limits for the parameter. When a Package is first built, most
values are set to 0. In many instances this will not be valid value, and the table or parameter will
display as containing invalid items.
Invalid items are displayed with a yellow triangle (as shown below). In this example, the valid
peak timer values are 0.3ms to 8.4ms, and the current parameter value is 0.0ms.
It is possible to search for all invalid parameters using the Invalid Configuration Data Summary
window, which is displayed by pressing
F7
. Within this window, it is possible to update the
parameters and channels to valid values.
Example of a the Invalid Configuration Data Summary