beautypg.com

Output commands – B&K Precision 9150-9153 - Manual User Manual

Page 37

background image

37

Parameter: 0~255

Reset value: Consult *PSC command

Example: STATus: OPERation:ENABle 128

Query syntax: STATus: OPERation:ENABle?

Return parameter:

Reference command: *PSC

Output Commands

OUTPut[:STATe]

This command sets the power supply output on or off.

Command syntax: OUTPut[:STATe]

Parameter: 0|1|ON|OFF

*RST value: OFF

Query syntax: OUTPut:STATe?

Return parameter: 0|1

Usage:

If output timer is required, send command OUTPUT:TIMER ON first, then set OUTPUT ON. These two
commands must be set in this order to function properly.

OUTPut:TIMer[:STATe]

This command sets the output timer state of the power supply.

Command syntax: OUTPut:TIMer[:STATe]

Parameter: 0|1|ON|OFF

*RST value: OFF

Query syntax: OUTPut:TIMer[:STATe]?

Return parameter: 0|1

Usage:

To start Timer

-

First, set OUTPUT:TIMER ON, then set OUTPUT ON.

To end Timer

-

Set OUTPUT:TIMER OFF to turn timer off.

To check timer status

-

Send command OUTPUT:TIMER?

OUTPut:TIMer:DATA

This command sets the time of the ou

t

put timer. The unit is in SECOND and decimal fractions cannot be

used for this command.

Command syntax: ONPut:TIMer:DATA

Parameter:

*RST value: 1
Query syntax: OUPut:TIMer:DATA?

Return parameter:

[SOURce:]MODE

This command configures the power supply for command fixed mode, list mode or DVM mode.

FIXed Command fixed mode
LIST List mode
DRM

Digital milliohm meter

Command syntax: [SOURce:]MODE

Parameter: FIXed|LIST|DRM

*RST value: FIXed

This manual is related to the following products: