beautypg.com

Options – Atec Rohde-Schwarz-ZVA Series User Manual

Page 31

background image

Version 10.00, May 2012

Rohde & Schwarz

R&S

®

ZVA Vector Network Analyzer 31

Options

Generator step attenuators

R&S

®

ZVA8, R&S

®

ZVA24, and R&S

®

ZVA40:

Generator step attenuators extend the lower limit of the output power range by 70 dB.
R&S

®

ZVA50 and R&S

®

ZVA67:

Generator step attenuators extend the lower limit of the output power range by 50 dB.

Frequency range

R&S

®

ZVA8

300 kHz to 8 GHz

R&S

®

ZVA24

10 MHz to 24 GHz

R&S

®

ZVA40

10 MHz to 40 GHz

R&S

®

ZVA50

10 MHz to 50 GHz

R&S

®

ZVA67

10 MHz to 67 GHz

Power range

R&S

®

ZVA8

300 kHz to 8 GHz

upper limit is reduced by 1 dB

300 kHz to 8 GHz

lower limit is extended by 70 dB

R&S

®

ZVA24

10 MHz to 13 GHz

upper limit is reduced by 1 dB

13 GHz to 24 GHz

upper limit is reduced by 2 dB

10 MHz to 24 GHz

lower limit is extended by 70 dB

R&S

®

ZVA40

10 MHz to 13 GHz

upper limit is reduced by 1 dB

13 GHz to 24 GHz

upper limit is reduced by 2 dB

24 GHz to 40 GHz

upper limit is reduced by 3 dB

10 MHz to 40 GHz

lower limit is extended by 70 dB

R&S

®

ZVA50

10 MHz to 13 GHz

upper limit is reduced by 1 dB

13 GHz to 24 GHz

upper limit is reduced by 2 dB

24 GHz to 50 GHz

upper limit is reduced by 3 dB

10 MHz to 50 GHz

lower limit is extended by 50 dB

R&S

®

ZVA67

10 MHz to 13 GHz

upper limit is reduced by 1 dB

13 GHz to 24 GHz

upper limit is reduced by 2 dB

24 GHz to 67 GHz

upper limit is reduced by 3 dB

10 MHz to 67 GHz

lower limit is extended by 50 dB

Power accuracy

at –10 dBm without power calibration

identical to specifications
without optional step attenuators

Power linearity
(with ALC off)

R&S

®

ZVA8, R&S

®

ZVA24, and R&S

®

ZVA40

above –70 dBm

< 2 dB

from –70 dBm to –100 dBm

< 3 dB

R&S

®

ZVA50 and R&S

®

ZVA67

above –50 dBm

< 2 dB

from –50 dBm to –80 dBm

< 3 dB

Dynamic range

R&S

®

ZVA8

300 kHz to 8 GHz

is reduced by 1 dB

R&S

®

ZVA24

10 MHz to 13 GHz

is reduced by 1 dB

13 GHz to 24 GHz

is reduced by 2 dB

R&S

®

ZVA40

10 MHz to 13 GHz

is reduced by 1 dB

13 GHz to 24 GHz

is reduced by 2 dB

24 GHz to 40 GHz

is reduced by 3 dB

R&S

®

ZVA50

10 MHz to 13 GHz

is reduced by 1 dB

13 GHz to 24 GHz

is reduced by 2 dB

24 GHz to 50 GHz

is reduced by 3 dB

R&S

®

ZVA67

10 MHz to 13 GHz

is reduced by 1 dB

13 GHz to 24 GHz

is reduced by 2 dB

24 GHz to 67 GHz

is reduced by 3 dB