Noise level
(without optional step attenuators
and without optional direct
generator/receiver access)
at 10 Hz measurement bandwidth
R&S
®
ZVA8
300 kHz to 100 MHz
< –100 dBm
100 MHz to 8 GHz
< –115 dBm
R&S
®
ZVA24
10 MHz to 100 MHz
typ. < –80 dBm
100 MHz to 700 MHz
< –80 dBm
700 MHz to 2 GHz
< –110 dBm
2 GHz to 13 GHz
< –115 dBm
13 GHz to 24 GHz
< –110 dBm
R&S
®
ZVA40
10 MHz to 100 MHz
typ. < –80 dBm
100 MHz to 500 MHz
< –80 dBm
500 MHz to 2 GHz
< –110 dBm
2 GHz to 20 GHz
< –115 dBm
20 GHz to 24 GHz
< –110 dBm
24 GHz to 32 GHz
< –105 dBm
32 GHz to 40 GHz
< –100 dBm
R&S
®
ZVA50
10 MHz to 100 MHz
typ. < –80 dBm
100 MHz to 500 MHz
< –100 dBm
500 MHz to 24 GHz
< –115 dBm
24 GHz to 40 GHz
< –110 dBm
40 GHz to 50 GHz
< –100 dBm
R&S
®
ZVA67
10 MHz to 100 MHz
typ. < –80 dBm
100 MHz to 500 MHz
< –105 dBm
500 MHz to 2 GHz
< –110 dBm
2 GHz to 24 GHz
< –118 dBm
24 GHz to 40 GHz
< –105 dBm
40 GHz to 50 GHz
< –102 dBm
50 GHz to 67 GHz
< –100 dBm
Noise level at optional measurement input
(direct generator/receiver access option)
at 10 Hz measurement bandwidth
R&S
®
ZVA8
100 MHz to 8 GHz
typ. < –130 dBm
R&S
®
ZVA24
100 MHz to 24 GHz
typ. < –130 dBm
R&S
®
ZVA40
100 MHz to 24 GHz
typ. < –130 dBm
24 GHz to 40 GHz
typ. < –120 dBm
R&S
®
ZVA50
100 MHz to 24 GHz
typ. < –130 dBm
24 GHz to 40 GHz
typ. < –120 dBm
40 GHz to 50 GHz
typ. < –115 dBm
R&S
®
ZVA67
100 MHz to 24 GHz
typ. < –130 dBm
24 GHz to 40 GHz
typ. < –120 dBm
40 GHz to 50 GHz
typ. < –115 dBm
50 GHz to 67 GHz
typ. < –110 dBm
The noise level is defined as the RMS value of the indicated noise floor. For the R&S
®
ZVA67 at single frequencies below 2.5 GHz,
the noise level may be affected by spurious signals.