beautypg.com

E-series cw power sensor specifications, E-series power sensor specifications – Atec Agilent-8480 Series User Manual

Page 9

background image

Power Linearity
Table 7

Power

Temperature (25 ºC ±5 C)

Temperature (0 to 55 ºC)

100 pW to 10 mW

±3 %

±7 %

(-70 dBm to +10 dBm)

10 mW to 100 mW

±4.5 %

±10 %

(+10 dBm to +20 dBm)

E-Series CW Power Sensor Specifications

Wide Dynamic Range CW Sensors: 100 pW to 100 mW (-70 dBm to +20 dBm).

Table 6

Model

Frequency Range

Maximum SWR

Maximum Power

Connector Type

E4412A

10 MHz – 18 GHz

*10 MHz to 30 MHz: 1.12

200 mW (+23 dBm)

Type-N (m)

30 MHz to 2 Ghz:1.15
2 GHz to 6 Ghz:1.17
6 GHz to 11 Ghz:1.2
11 GHz to 18 Ghz:1.27

E4413A

50 MHz – 26.5 GHz

50 MHz to 100 MHz: 1.21

200 mW (+23 dBm)

APC-3.5mm (m)

100 MHz to 8 Ghz:1.19
8 GHz to 18 Ghz:1.21
18 GHz to 26.5 Ghz:1.26

9

Figure 1 : Relative Mode Power Measurement Linearity with EPM series
power meter/E-series CW power sensor at 25°C±5°C (typical)

* applies to sensors with serial prefix US 3848 or greater

Power Level Used as Reference (dBm)

Power Level Being Measured (dBm)

+20

+10

+6

-20

-35

-70

-70

-35

-20

-10

+10

+20

±4%

+3%

±1%

A

B

E-series Power Sensor Specifications

The E-series of power sensors have their Calibration Factors stored in EEPROM and operate over a wide dynamic range.
They are designed for use with the EPM series of power meters and two classes of sensors are available:

• CW power sensors (E4412A and E4413A).
• Average power sensors (E9300 sensors).