Performance Characteristics and Specifications
Supplemental characteristics are not specifications, but are provided in
for your convenience.
Interference Standards
The IEC/EN 61326- 1 and CISPR Publication 11 standards define the RFI
and EMI susceptibility of the performance modeling system.
Performance Modeling System Performance Specifications
The Agilent 85225F performance modeling system adheres to the
performance specifications of an Agilent E8364B PNA Series vector
network analyzer. Refer to
, “Network Analyzer Performance
Specification Summary,” starting on page 141.
Table 15 Supplemental System Characteristics
Characteristic
Value
Line voltage
115 volts nominal (90 volts to 132 volts) or 220 volts nominal
(210 volts to 250 volts)
Line frequency
48 Hz to 66 Hz
Circuit breaker amperage rating
6 amps (115 volts), 3.5 amps (220 volts)
Rack weight capacity
818 kilograms (1800 pounds) maximum loaded
Rack external dimensions
1620 mm high
×
600 mm wide
×
905 mm deep
Rack footprint (top view)