Contact Closure Remote Control

For contact closure, connect a contact closure remote control device to the contact closure
female 5-pole captive screw connector of the front panel. Various AAP devices and cable
assemblies are also available from Extron to provide remote contact closure capability.
The pin assignments for the contact closure connector of the RGB 580xi are shown in the
following table.

Pin

Contact Closure

Description

A

Contact closure +

Contact closure + circuit

B

Contact closure -

Contact closure - circuit

C

+5 V

+5 V source for powering AAP devices

D

Gnd

Signal ground for powering AAP devices

E

-5V

-5 V source for powering AAP devices

RGB 580xi • Connection and Configuration