SMX System MultiMatrix Switcher • SIS Programming Guide

Command

ASCII Command

(host to switcher)

Response

(switcher to host)

Additional Description

EDID (Extended Display Identification Data) Commands

Assign EDID data to input

E

A

X3)

*

X!

*

X3@

EDID

}

X3)

EdidA

X!

*

X3@

]

Assign EDID data to all inputs

E

A

X3)

*

X3@

*EDID

}

X3)

EdidA00

*

X3@

]

Save output 1 EDID data to user

space

E

S

X3)

*

X3@

EDID

}

X3)

EdidS

X3@

]

Applies only where

X3@

= 37 to 40.

V

iew EDID data assignment

E

A

X3)

*

X!

EDID

}

X3@

]

X3)

EdidA

X!

*

X3@

]

V

erbose mode 2 or 3

Export EDID file data

E

E

X3)

*

X3@

EDID

}

X6)

]

X3)

EdidE

X3@

*

X6)

]

V

erbose mode 2 or 3

Import EDID file data to user file

location

E

I

X3)

*

X3@

EDID

}

X6)

X3)

EdidI

X3@

]

Applies only where

X3@

= 37 to 40

NOTE:

For the

EDID table

, see page 21 or refer to the online

SMX User Guide

.

NOTES:

X!

= Input number

01

- <

maximum number of inputs

>

X3)

= Slot address

01

-

10

X3@

= EDID reference file for DDC data

00

-

40

, where

15

= default,

1

-

8

= stored from connected EDID monitors as

reference,

9

-

36

= factory fixed rates,

37

-

40

= user definable

X6)

= EDID file data block

128 bytes of binary data