Using reset levels, Reset mode uses – Extron Electronics SMX System Setup Guide User Manual
Page 22
16
SMX System MultiMatrix Switcher • Front Panel Operation
Using Reset Levels
The rear panel has a recessed Reset button (see
four levels of resets (numbered 1, 3, 4, and 5). Use a pointed stylus,
ballpoint pen, or Extron Tweeker to access it and select the reset level.
See the
on page 17 for a summary of the modes.
CAUTION:
Review the reset modes carefully. Using the wrong
reset mode may result in unintended loss of flash
memory programming, port reassignment, or a
controller reboot.
NOTES:
•
The reset modes listed below close all open IP and
Telnet connections and sockets. Also, the following
modes are separate functions, not a continuation from
mode 1 to mode 5.
•
If the reset button is continuously held down, the I/O
lights flash every 3 seconds as the next reset level is
reached, corresponding to modes 3, 4, and 5.
Reset Mode Uses
Use mode 1 to revert to the factory default firmware version if
compatibility issues arise with user-loaded firmware (see
on
page 17).
Use mode 3 to restart the communication and control events.
Use mode 4 to reset most IP protocols to their default settings.
Use mode 5 to restore the switcher to the default conditions.
NOTE: Mode 5 reset clears most adjustment. To save these
settings, use the SMX Control Program and the File >
Save MATRIX settings as...
selection before you
page 32).
RESET
RESET
RESET
RESET
Release, then
immediately
press and release again. Reset
LED flashes in confirmation.
Modes 3, 4, and 5
Press and
hold
the Reset button.
Mode 1
Reset LED flashes
once,
twice, or three times.
Press and
hold for
3, 6, or 9 seconds.
Apply Power
1
2
RESET
Release the Reset button.