Reset mode table, Notes – Extron Electronics SMX System Setup Guide User Manual
Page 23
17
SMX System MultiMatrix Switcher • Front Panel Operation
Reset Mode Table
Mode
Action
Result
1
Hold down the recessed
Reset button while applying
power to the switcher.
Defaults switcher to factory installed
firmware. Event scripting will not start if
the switcher is powered on in this mode. All
user files and settings (drivers, adjustments,
IP settings, and so on) are maintained (see
3
Hold down the Reset button
for 3 seconds, until the Reset
LED blinks once, then press
Reset momentarily
(<1 second) within 1 second.
Mode 3 turns events on or off. During
resetting, the Reset LED flashes 2 times if
events are starting, 3 times if events are
stopping.
4
Hold down the Reset button
for 6 seconds, until the Reset
LED blinks twice (once at 3
seconds, again at 6 seconds)
then press Reset momentarily
(<1 second) within 1 second.
Mode 4:
•
Enables ARP capability
•
Sets IP address to factory default
•
Sets subnet address to factory default
•
Sets gateway address to factory default
•
Sets port mapping to factory default
•
Turns DHCP off
•
Turns events off
The Reset LED flashes four times in quick
succession confirming the Reset.
5
Hold down the Reset button
for 9 seconds, until the Reset
LED blinks three times (once
at 3 seconds, again at 6
seconds, and then again at
9 seconds). Then press Reset
momentarily (<1 second)
within 1 second.
Mode 5 performs a complete reset to
factory defaults (with the exception of the
firmware):
•
Does everything mode 4 does
•
Resets almost all real time adjustments:
clears all ties and presets, clears all audio
or RS-232 mutes, clears all I/O grouping,
clears all RGB delay settings to zero, and
clears all input and output audio settings
(see the SMX User Guide for more details
on these features)
•
Resets all IP options
•
Removes/clears all files for the SMX
The reset LED flashes four times in quick
succession confirming the reset.
NOTES:
•
After a mode 1 reset is performed, update the firmware
to the latest version. Do not operate the SMX firmware
version that results from the mode 1 reset. To use factory
default firmware, upload that version again.
•
If you do not want to update firmware, or you performed
a mode 1 reset by mistake, cycle power to the SMX to
return to the firmware version that was running before
the mode 1 reset. Use the 0Q SIS command to confirm
that the factory default firmware is no longer running
(look for the asterisk [*] following the version number.