Preliminar y preliminar y, Serial communication, cont’d – Extron Electronics PVS 305SA User Guide User Manual
Page 32
![background image](/manuals/312171/32/background.png)
Serial Communication, cont’d
PVS 305SA • Serial Communication
4-4
PRELIMINAR
Y
PRELIMINAR
Y
X#
= Status,
0 = off/disable (default)
1 = on/enable
= Signal detection threshold
0 = off (signal level too low to detect)
1 = on (a signal of a least -20 dBv [-18 dBu] is present)
= Normal range
0 = off (input level is too low)
1 = on (input is in the right range)
= Peak level
0 = off (audio input is set up correctly)
1 = on (the level or gain is too high, audio clips/distorts. Output equipment could be
damaged. Adjust the input level so that only the Normal LED is blinking. The Peak
LED should not turn on)
X$
= 0 – 14, bass and treble adjustment range, +/- 10.5 dB in 1.5 dB increments/decrements,
Value
dB
0
-10.5
1
-9.0
2
-7.5
3
-6.0
4
-4.5
5
-3.0
6
-1.5
7
0.0
8
+1.5
9
+3.0
10
+4.5
11
+6.0
12
+7.5
13
+9.0
14
+10.0
X%
= -10.5 to +10.5, bass and treble, readout in dB
X^
= 0 – 100, volume, default = 50
X&
= 0 – 24, input gain adjustment range, 0 through +24 dB, in 1 dB steps, (default = 0)
X*
= 0 – 18, input attenuation adjustment range, 0 through -18 dB, in 1 dB steps.
X(
= -18 to + 24, input gain and attenuation readout, in dB
X1)
= -10 through +10, power amp gain readout, in dB, (default = 0)
X1!
= Power save mode/state
0 = auto power save and standby power mode off (power save off)
1 = set auto power save timer running, but not triggered
2 = auto power save on (timer triggered)
3 = standby power save on
X1@
= 0 thru 20, power amp attenuation adjustment range, (+/-10 dB in 1 dB increment/
decrement)
X1#
= Status
0 = not present/malfunction
1 = present/OK
X1$
= Internal temperature
X2)
= Version and build number (x.xx.xxxx)
X2!
= Version (x.xx)
X2@
= RGB delay in 0.5 second steps; 0 = 0 seconds, 1 = 0.5 seconds, ...10 = 5.0 seconds