Serial Communication, cont’d

PVS 305SA • Serial Communication

4-4

PRELIMINAR

Y

PRELIMINAR

Y

X#

= Status,

0 = off/disable (default)

1 = on/enable

= Signal detection threshold

0 = off (signal level too low to detect)

1 = on (a signal of a least -20 dBv [-18 dBu] is present)

= Normal range

0 = off (input level is too low)

1 = on (input is in the right range)

= Peak level

0 = off (audio input is set up correctly)

1 = on (the level or gain is too high, audio clips/distorts. Output equipment could be

damaged. Adjust the input level so that only the Normal LED is blinking. The Peak

LED should not turn on)

X$

= 0 – 14, bass and treble adjustment range, +/- 10.5 dB in 1.5 dB increments/decrements,

Value

dB

0

-10.5

1

-9.0

2

-7.5

3

-6.0

4

-4.5

5

-3.0

6

-1.5

7

0.0

8

+1.5

9

+3.0

10

+4.5

11

+6.0

12

+7.5

13

+9.0

14

+10.0

X%

= -10.5 to +10.5, bass and treble, readout in dB

X^

= 0 – 100, volume, default = 50

X&

= 0 – 24, input gain adjustment range, 0 through +24 dB, in 1 dB steps, (default = 0)

X*

= 0 – 18, input attenuation adjustment range, 0 through -18 dB, in 1 dB steps.

X(

= -18 to + 24, input gain and attenuation readout, in dB

X1)

= -10 through +10, power amp gain readout, in dB, (default = 0)

X1!

= Power save mode/state

0 = auto power save and standby power mode off (power save off)

1 = set auto power save timer running, but not triggered

2 = auto power save on (timer triggered)

3 = standby power save on

X1@

= 0 thru 20, power amp attenuation adjustment range, (+/-10 dB in 1 dB increment/

decrement)

X1#

= Status

0 = not present/malfunction

1 = present/OK

X1$

= Internal temperature

X2)

= Version and build number (x.xx.xxxx)

X2!

= Version (x.xx)

X2@

= RGB delay in 0.5 second steps; 0 = 0 seconds, 1 = 0.5 seconds, ...10 = 5.0 seconds