GE Industrial Solutions HW006-010-012 Series User Manual
Page 5

Lineage Power
5
Data Sheet
June 26, 2009
36-75 Vdc Input; 1.2 Vdc to 5 Vdc Output; 6.6A to 12A
HW006/010/012 Series Power Modules; dc-dc Converters
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information
.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Remote On/Off Signal interface
(VI = VI, min to VI, max; Open collector or compatible, signal
referenced to VI (-) terminal
Negative Logic: Device code with suffix "1"
Logic Low—Module On / Logic High—Module Off
Positive Logic: If device code suffix "1" is not specified
Logic Low—Module Off / Logic High—Module On
Module Specifications:
On/Off Current—Logic Low
On/Off Voltage:
Logic Low
Logic High
Open Collector Specifications:
Leakage Current during Logic High
(Von/off = 15 V)
Output Low Voltage during Logic Low
(Ion/Off – 1 mA)
All
All
All
All
All
Ion/off
Von/off
Von/off
Ion/off
Von/off
—
–0.7
—
—
—
—
—
—
—
—
1.0
1.2
15
50
1.2
mA
V
V
µA
V
Turn-On Delay and Rise Times
(IO = 80% of IO, max, VIN = 48 Vdc, TA = 25 °C)
Case 1: On/Off input is set to Logic high and then input power
is applied (delay from instant at which VI = VI, min until VO =
10% of VO, set)
Case 2: Input power is applied for at least one second and
then the On/Off input is set to logic high (delay from instant at
which Von/off = 0.9 V until VO = 10% of VO, set)
Output voltage Rise time (time for VO to rise from 10% of VO,
set to 90% of VO, set)
All
All
All
Tdelay
Tdelay
Trise
—
—
—
25
25
0.9
—
—
—
msec
msec
msec
Output voltage overshoot
(IO = 80% of IO, max, VI = 48 Vdc TA = 25 °C)
All
—
—
5
%VO, set
Output voltage adjustment (see Feature Description section)
Output voltage set-point adjustment range (TRIM)
ALL
90
—
110
%VO, set
Output Overvoltage Protection (clamp)
HW012A0P1
HW012A0M1
HW012A0Y1
HW010A0G1
HW010A0F1
HW006A6A1
VO, ovsd
VO, ovsd
VO, ovsd
VO, ovsd
VO, ovsd
VO, ovsd
—
—
—
—
—
—
2.0
2.3
2.3
3.1
4.0
6.1
2.8
3.2
3.2
3.7
4.6
7.0
V
V
V
V
V
V
Overtemperaute Protection (IO = IO, max)
See Figure 44
All
TQ203
—
125
—
°C
Input Undervoltage Lockout
Turn-on Threshold
Turn-off Threshold
All
All
—
25
32
27
36
—
V
V