G output strip, G input strip, Ge others – GE Industrial Solutions ZBTE Series User Manual
Page 6: Ge zenith, Controls, Others, Ge zenith controls, Non-bypass ats bypass ats

91
R
-1000
Page 4
Zenith ZTE/ZBTE Series Operation & Maintenance Manual
Figure 3
Representative Schematic of Terminal Board, Output Strip and Input Strip
Refer to Electrical Schematic Drawing for additional details
CUSTOMER USE
A1
OUT5
11
MX350 C
ONTR
OLLER
TO
L-CARD SL
O
T “G” ON
G OUTPUT STRIP
OUTPUT-5
12
A2
14
5-3
5-2
L5
L6
L4
L3
L2
L1
G2
G6
G4
G5
G3
J8
G1
800
802
J7
2
1
-
+
OUTPUT-4
FACTORY USED (FOR ALARM)
FOR CUSTOMER USE
STATUS OUTPUT CONTACT
SHUNT TRIP EMERG. BKR.
LOAD SHED
STATUS OUTPUT CONTACT
FOR CUSTOMER USE
GE ZENITH
12
12
OUT4
A1
A2
OUT3
A1
A2
14
11
11
14
CONTROLS
12
12
A1
OUT1
OUT2
A2
A1
A2
11
14
11
14
802
4-2
4-3
5-1
4-1
3-3
3-2
2-3
3-1
1-3
2-2
1-2
2-1
1-1
(-)
OUTPUT
CONTACTS FOR
CONFIGURABLE
OTHERS
G INPUT STRIP
L9
MX350 C
O
NTR
OLLER
TO
L-CARD SL
O
T “G” ON
L13
L14
L12
L11
L10
G9
G13
G14
G12
G10
G11
L7
L8
802
800
J6
G8
G7
1
2
J5
-
+
(SUPPLIED BY OTHERS)
(SUPPLIED BY OTHERS)
(SEE NOTE 3)
(SEE NOTE 4)
(SEE NOTE 8)
C
C
NO
12
12
12
IN7
A2
A1
IN5
IN6
A2
A1
A2
A1
14
11
14
11
14
11
COM
13
12
25ZA
NO
NO
C
C
C
C
IN1
11
A1
12
12
12
12
IN3
A1
IN4
A1
A2
A2
IN2
A1
A2
A2
11
11
14
14
11
14
14
GE ZENITH
CONTROLS
11
10
9
7
8
R15
NO
NO
C
C
C
C
Q2
DS
NO
C
FOR CUST
OMER USE
C
O
NFIGURABLE INPUTS OPTION P
A
CKA
GE
OTHERS
COM
COM
CONNECTIONS OF THE TRANSFER SWITCH.
COMPONENTS DRAWN IN DASHED LINES ARE OPTION PACKAGE AND CUSTOMER
Q2 (TEST WITH LOAD) IS PROVIDED AS STANDARD (PRE-CONFIGURED) FEATURE.
R15 (LOAD SHED) IS PROVIDED AS AN OPTION (PRE-CONFIGURED) FEATURE.
ATS SHOWN IN SOURCE-1 POSITION WITH NO POWER AVAILABLE.
UNLESS OTHERWISE SPECIFIED ALL CUSTOMER CONNECTION WIRES TO BE #14 AWG.,
OUTPUT STRIP CONTACTS ARE RATED 10 AMPS AT 30VDC/250VAC.
ENGINE START CONTACT IS RATED 10 AMPS AT 28VDC/120VAC.
600V.
6.
7.
5.
4.
3.
2.
1.
NOTES
8. ENGINE START CONTACT MAY BE ON SEPARATE TERMINAL BLOCK FOR BYPASS
SWITCHES. REFER TO ELECTRICAL SCHEMATIC FOR TERMINAL LOCATION.
GE
OTHERS
A4-1
A3-1
A3-2
CARD
8
K
8
C
C
C
7
9
E12
E11
E13
NO
NO
NO
A3-2
CA3-1
A3-1
CA4-1
A4-1
CA3-2
A4-2
C
AUX
NO
CA4-2
A4-2
CLOSED IN SOURCE 2 POSITION.
(2) NORMALLY OPEN CONTACTS.
FOR CUSTOMER USE.
FOR CUSTOMER USE
CONTACT
E
ENGINE START CONTACT
(2) NORMALLY OPEN CONTACTS
TB
FOR CUSTOMER USE.
HELD CLOSED IN SOURCE 1 POSITION
CARD
K
TB
ENG. START
98
8
7
8
9
PA3
TP1
E11
E13
E12
NO
NO
NO
NO
NO
NO
C
AB4-5
AB3-6
C
C
A3-1
C
A4-1
A3-2
C
A4-2
C
CA3-1
101
100
A3-1
CA3-2
99
CA4-1
CA4-2
A3-2
A4-1
A4-2
AUX
GE
OTHERS
(2) NORMALLY OPEN
CONTACTS, HELD CLOSED IN
SOURCE 1 POSITION FOR
CUSTOMER USE. SEE NOTE 1
(2) NORMALLY OPEN
CONTACTS, CLOSED IN
SOURCE 2 POSITION
FOR CUSTOMER USE.
IS IN SOURCE 1 POSITION.
CONTACT CLOSED WHEN BYPASS
FOR CUSTOMER USE.
CONTACT CLOSED WHEN BYPASS
IS IN SOURCE 2 POSITION.
FOR CUSTOMER USE.
CONTACT
E
FOR CUSTOMER USE
ENGINE START CONTACT
Non-Bypass ATS
Bypass ATS