Car0812fp series rectifier, Data sheet, Input: 85v – GE Industrial Solutions CAR0812FP series User Manual
Page 6: Output: 12v, Or 5 v, Environmental specifications, Emc compliance

GE
Data Sheet
CAR0812FP series rectifier
Input: 85V
AC
to 264V
AC
; Output: 12V
DC
@ 850W; 3.3V
DC
or 5 V
DC
@ 1A
May 2, 2013
©2013 General Electric Company. All rights reserved.
Page 6
Environmental Specifications
Parameter
Min
Typ
Max
Units
Notes
Ambient Temperature
-10
6
70
°C
Derated above 50C
Storage Temperature
-40
85
°C
Operating Altitude
2250/7382
m/ft
Non-operating Altitude
8200/30k
m / ft
Power Derating with Temperature
2.5
%/°C
50C to 70C
Power Derating with Altitude
2.0
C/301 m
C/1000 ft
Above 2250 m/7382 ft
Acoustic noise
55
dbA
Full load
Over Temperature Protection
125/110
°C
Shutdown / restart
Humidity
Operating
Storage
30
10
95
95
%
Relative humidity, non-condensing
Shock and Vibration acceleration
6
Grms
NEBS GR-63-CORE, Level 3, 20 -
2000Hz, min 30 minutes
Earthquake Rating
4
Zone
NEBS GR-63-CORE, all floors, Seismic
Zone 4 Designed and tested to meet
NEBS specifications.
EMC Compliance
Parameter
Criteria
Standard
Level
Test
AC input
7
Conducted emissions
EN55022, FCC Docket 20780 part 15, subpart J
EN61000-3-2
A – Z01A
B – Z01B
0.15 – 30MHz
0 – 2 KHz
Radiated emissions
EN55022
A – Z01A
B – Z01B
30 – 10000MHz
AC Input immunity
Voltage dips
EN61000-4-11
A
-30%, 10ms
B -60%,
100ms
B -100%,
5sec
Voltage surge
EN61000-4-5
A
2kV, 1.2/50µs, common mode
A
1kV, 1.2/50µs, differential mode
Fast transients
EN61000-4-4
B
5/50ns, 2kV (common mode)
Enclosure immunity
Conducted RF fields
EN61000-4-6
A
130dBµV, 0.15-80MHz, 80% AM
Radiated RF fields
EN61000-4-3
A
10V/m, 80-1000MHz, 80% AM
ENV 50140
A
ESD
EN61000-4-2
B
4kV contact, 8kV air
6
Designed to start at an ambient down to -40°C; meet spec after 30 min warm up period, may not meet operational limits below -10°C.
7
The ….Z01A module meets class A emissions, the …..Z01B module meets class B emissions (see ordering section)