Car0812fp series rectifier, Data sheet, Input: 85v – GE Industrial Solutions CAR0812FP series User Manual
Page 3: Output: 12v, Or 5 v, General specifications, Feature specifications

GE
Data Sheet
CAR0812FP series rectifier
Input: 85V
AC
to 264V
AC
; Output: 12V
DC
@ 850W; 3.3V
DC
or 5 V
DC
@ 1A
May 2, 2013
©2013 General Electric Company. All rights reserved.
Page 3
12V
dc
MAIN OUTPUT (continued)
Parameter
Symbol
Min
Typ
Max
Unit
Turn-ON delay
T
2
sec
Remote ON/OFF delay time
40
ms
Turn-ON rise time (10 – 90% of V
OUT
)
50
ms
Transient response 50% step [10%-60%, 50% - 100%]
(di/dt – 1A/µs, recovery 500µs)
V
OUT
-5 +5
%V
OUT
Programmable range (hardware & software)
10.8
13.2
V
DC
Overvoltage protection, latched
(recovery by cycling OFF/ON via hardware or software)
13.5 14.5 15.5
V
DC
Output current
I
OUT
0 71
A
DC
Current limit, Hiccup (level programmable)
106
125
% of FL
Active current share – greater than 20% load
-5
+5
% of FL
STANDBY OUTPUT
Parameter
Symbol
Min
Typ
Max
Unit
Set point
V
OUT
3.3 / 5.0
V
DC
Overall regulation (load, temperature, aging)
V
OUT
-5
+5 %
Ripple and noise
50
mVp-p
Output current
I
OUT
0 1
A
DC
Isolation Output/Frame
100
V
DC
General Specifications
Parameter
Min
Typ
Max
Units
Notes
Reliability
300,000
100,000
hrs
Full load, 25C per Bellcore RPP
Full load, 50C per Bellcore RPP
Service Life
10
Yrs
Full load, excluding fans
Weight
1.09
(2.4)
Kgs
(Lbs)
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature
Descriptions for additional information.
Parameter
Symbol
Min
Typ
Max
Unit
Remote ON/OFF (Needs to be pulled HI via an external resistor)
Logic High (Module ON)
I
IH
20 µA
V
IH
0.7V
DD
12 V
DC
Logic Low (Module OFF)
I
IL
1 mA
V
IL
0
0.8 V
DC