Car0812fp series rectifier, Data sheet, Input: 85v – GE Industrial Solutions CAR0812FP series User Manual
Page 5: Output: 12v, Or 5 v, Feature specifications (continued), Digital interface specifications

GE
Data Sheet
CAR0812FP series rectifier
Input: 85V
AC
to 264V
AC
; Output: 12V
DC
@ 850W; 3.3V
DC
or 5 V
DC
@ 1A
May 2, 2013
©2013 General Electric Company. All rights reserved.
Page 5
Feature Specifications (continued)
Parameter
Symbol
Min
Typ
Max
Unit
SMBAlert# (Interrupt) (Needs to be pulled HI via an external resistor)
Logic High (No Alert - normal)
I
OH
20 µA
V
OH
0.7V
DD
12 V
DC
Logic Low (Alert is set)
I
OL
4 mA
V
OL
0
0.4 V
DC
Output current monitor (Imon)
Resolution
40 mV/A
Accuracy, load greater than 25%
-10
10
%
Measurement range
I
o
0 80 A
DC
Analog output range
V
mon
0 3 V
DC
Sourced output current
I
o
5 mA
DC
Digital Interface Specifications
Parameter
Conditions
Symbol
Min
Typ
Max
Unit
PMBus Signal Interface Characteristics
Input Logic High Voltage (CLK, DATA)
V
IH
2.1 3.6 V
DC
Input Logic Low Voltage (CLK, DATA)
V
IL
0 0.8 V
DC
Input high sourced current (CLK, DATA)
I
IH
0 10 μA
Output Low sink Voltage (CLK, DATA, SMBALERT#)
I
OUT
=3.5mA V
OL
0.4 V
DC
Output Low sink current (CLK, DATA, SMBALERT#)
I
OL
3.5
mA
Output High open drain leakage current (CLK,DATA,
SMBALERT#)
V
OUT
=3.6V I
OH
0 10 μA
PMBus Operating frequency range
Slave Mode
F
PMB
10 400 kHz
Measurement System Characteristics (all measurement tolerances are typical estimations under normal operating conditions)
Clock stretching
t
STRETCH
25
ms
I
OUT
measurement range
Linear
I
RNG
0 80 A
DC
I
OUT
measurement accuracy 25°C
I
ACC
-5 +5 %
V
OUT
measurement range
Linear
V
OUT(rng)
0
14
V
DC
V
OUT
measurement accuracy
V
OUT(acc)
-5 +5 %
Temp measurement range
Linear
Temp
(rng)
0
120
C
Temp measurement accuracy
5
Temp
(acc)
-5 +5 %
I
IN
measurement range
Linear
I
IN(rng)
0 15 A
AC
I
IN
measurement accuracy
I
IN(acc)
-5 +5 %
V
IN
measurement range
Linear
V
IN(rng)
0 300 V
AC
V
IN
measurement accuracy
V
IN(acc)
-5 +5 %
P
IN
measurement range
Linear
P
N(rng)
0 1000 W
P
IN
measurement accuracy
P
IN(acc)
-5 +5 %
Fan Speed measurement range
Linear
0 30k RPM
Fan Speed measurement accuracy
-10 10 %
Fan speed control range
Linear
0 100 %
5
Temperature accuracy reduces non-linearly with decreasing temperature