Car0812fp series rectifier, Data sheet, Input: 85v – GE Industrial Solutions CAR0812FP series User Manual
Page 2: Output: 12v, Or 5 v, Absolute maximum ratings, Electrical specifications

GE
Data Sheet
CAR0812FP series rectifier
Input: 85V
AC
to 264V
AC
; Output: 12V
DC
@ 850W; 3.3V
DC
or 5 V
DC
@ 1A
May 2, 2013
©2013 General Electric Company. All rights reserved.
Page 2
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional
operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure
to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Symbol
Min
Max
Unit
Input Voltage: Continuous
V
IN
0
264
V
AC
Operating Ambient Temperature
T
A
-10
70
1
°C
Storage Temperature
Tstg
-40
85
°C
I/O Isolation voltage to Frame (100% factory Hi-Pot tested)
1500
V
AC
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, load, and temperature conditions.
INPUT
Parameter
Symbol
Min
Typ
Max
Unit
Operational Range
V
IN
85
2
110/230 264 V
ac
Frequency Range
F
IN
47 50/60 63 Hz
Main Output Turn_OFF
V
IN
68 75
V
AC
Main Output Turn ON
V
IN
76 84
V
AC
Maximum Input Current V
IN
= 100V
AC
I
IN
11
6.1
A
AC
(V
OUT
= V
O, set
, I
OUT
=I
O, max
) V
IN
= 180V
AC
Cold Start Inrush Current
I
IN
40
A
PEAK
(Excluding x-caps, 25C, <10ms, per ETSI 300-132)
Efficiency (T
AMB
=25C, V
OUT
= 12V, I
O, max
)
230V 115V
90 87
%
100% load
75% load
91 89
50% load
92.5 90
20% load
90 88
10% load
82.5 83
Power Factor (Vin=230V
AC
, I
OUT
=I
O, max
)
PF
0.99
Holdup time
3
(T
AMB
25C, V
OUT
= 12V
DC
,
I
OUT
= I
O, max
)
T 12 ms
Early warning prior to output falling below regulation
T
2
ms
Leakage Current (V
IN
= 250V
AC
, Fin = 60Hz)
I
IN
3
DC
Isolation Input/Output
3000 V
AC
Input/Frame
1500 V
AC
Output/Frame
100
V
DC
12V
dc
MAIN OUTPUT
Parameter
Symbol
Min
Typ
Max
Unit
Output Power V
IN
> 90V
AC
W
0 - 850
W
V
IN
≤ 90V
AC
0 - 750
Set point
V
OUT
11.9 12.00 12.1 V
DC
Overall regulation (line, load, temperature)
-2
+2
%
Ripple and noise
4
V
OUT
120
mVp-p
Turn-ON overshoot
+3
%
1
Derated above 50C at 2.5%/C
2
Unit derates to 750W below 90Vac.
3
12V output can decay down to 10.8V
4
Measured across a 10µf electrolytic and a 0.1µf ceramic capacitors in parallel. 20MHz bandwidth