Af-60 lp™ micro drive programming guide – GE Industrial Solutions AF-60 LP Micro Drive User Manual
Page 66

6-
13 Terminal 53 H
ig
h
Current
0.01 - 20.00
mA
* 20.00
mA
6-
14 Term.
53 Low Ref./Feed
b. Va
lu
e
-4999 - 4
999 * 0
.00
0
6-
15 Term.
53 High
Ref.
/Feedb
. Value
-4999 - 4
999 * 5
0
.0
00
6-
16 Terminal 53 Fil
ter
T
im
e
Co
nstant
0.01 - 10.00
s * 0.01
s
6-
19
Terminal 5
3
m
o
de
*[0] Vol
tage
m
o
de
[1] Curr
ent mod
e
6-
2
* Analo
g
Input 2
6-
22 Terminal 60 Low Current
0.00 - 19.99
mA
* 0.14 m
A
6-
23 Terminal 60 H
ig
h
Current
0.01 - 20.00
mA
* 20.00
mA
6-
24 Term.
60 Low Ref./Feed
b. Va
lu
e
-4999 - 4
999 * 0
.00
0
6-
25 Term.
60 High
Ref.
/Feedb
. Value
-4999 - 4
999 * 5
0
.0
0
6-
26 Terminal 60 Fil
ter
T
im
e
Co
nstant
0.01 - 10.00
s * 0.01
s
6-
8* Keypad
pot
enti
omet
er
6-
81 Keypa
d
po
tm.
L
o
w Reference
-4999 - 4
999 * 0
.00
0
6-
82 Keypa
d
po
tm.
High Reference
-4999 - 4
999 * 5
0
.0
0
6-
9* Anal
og
O
u
tput xx
6-
90
Terminal 4
2
M
o
de
*[0] 0-2
0 m
A
[1] 4-20 m
A
[2] Digita
l O
u
tput
6-
91 Terminal 42 An
alog Outp
u
t
*[0] No
ope
rat
ion
[10] O
u
tp
ut
Fr
equ
e
n
cy
[11] R
e
fe
re
nc
e
[12] Feedb
ack
[1
3
] M
o
to
r
Cu
rr
e
n
t
[16] Power
[20] Bu
sC
ont
rol
6-
92 Terminal 42 Digital Output
Se
e par
. 5-40
* [0]
No
Oper
atio
n
[80] L
o
gic C
o
n
trol
le
r Di
git
al Ou
tpu
t A
6-
93 T
e
rminal 42 Output Min Scale
0.00 - 2
00.0 % * 0.00 %
6-
94 T
e
rminal 42 Output Max Scale
0.00 - 2
00.0 % * 100.0 %
7-
** C
o
n
trol
le
rs
7-
2*
Proce
ss Ctrl. Fe
edb
7-
20 Pro
c
ess CL Feedback 1 R
e
sourc
e
*[
0]
N
o
Fun
ctio
n
[1] Analog Input 53
[2] Analog inp
ut
60
[8] PulseInput
33
[11] Lo
ca
lBu
sRef
7
-3
* Pr
o
c
e
ss
PI
Ctrl. 7-30
P
rocess PI
Norma
l/
Inverse Ctrl
*[
0]
No
rm
a
l
[1] Inverse
7-
31 Pro
c
ess PI An
ti
Wind
u
p
[0] Disable
*[
1
] E
n
able
7-
32 Pro
c
ess PI Start Speed
0.0 - 20
0.
0
Hz * 0.0 Hz
7-
33 Pr
o
c
ess
PI Pr
op
ort
ion
al
Ga
in
0.00 - 1
0
.0
0 *
0.01
7-
34 Pro
c
ess PI Integra
l T
im
e
0.10 - 9
999 s *
9999 s
7-38 Pr
oc
ess
PI Fe
ed For
war
d
Factor
0 - 40
0 % *
0
%
7-
39 On Reference Ban
dwidth
0 - 20
0 % *
5
%
8-
**
Co
m
m
. and
O
p
ti
ons
8-
0* Gener
a
l Set
ti
ngs
8-
01 Control Si
te
*[
0]
D
igi
ta
l an
d
C
o
n
tro
lW
or
d
[1] Digital
only
[2] C
o
nt
rolWo
rd only
8-
02 Control Word
Source
[0] None
*[
1]
G
E
D
ri
ve
R
S
48
5
8-
03 Control Word
T
imeo
u
t Time
0.1 - 65
00 s * 1
.0
s
8-
04 Control Word
T
imeo
u
t Functi
o
n
*[
0]
Of
f
[1] Freez
e
Outp
ut
[2] Stop
[3] J
o
gging
[4] Max.
Spe
ed
[5] Stop a
n
d
tr
ip
8
-06 R
e
set Con
trol Word Timeout
*[0] N
o
F
uncti
o
n
[1] D
o
r
e
set
8-
3
* G
E
D
ri
v
e Po
rt
Se
tt
ing
s
8
-30 Protocol
*[0] GE Dri
ve
[2] Modb
us
RTU
8
-31 Address
1
- 247 *
1
8
-32 GE Dri
ve Port Ba
ud
R
a
te
[0] 24
00 B
a
u
d
[1] 48
00 B
a
u
d
*[2] 960
0 B
a
u
d
[3] 19200 Ba
ud
*[4] 384
00 B
a
u
d
8
-33 GE Dri
ve Por
t Pari
ty
*[0] Even
Par
ity, 1 Stop
Bi
t
[1] Odd Pa
rit
y, 1
St
op Bit
[2] No Par
ity, 1 Stop
Bit
[3] No Par
ity, 2 Stop
Bits
8-
3
5
Mi
ni
mu
m R
e
sp
o
n
se
D
e
la
y
0
.00
1-0.5
* 0.010 s
8
-36 M
a
x Re
sp
ons
e Delay
0
.10
0 - 10.00 s * 5.000
s
8-
5
* D
ig
ita
l/
B
u
s
8
-50 Coasting Select
[0] Digita
lInp
ut
[1] Bus
[2] L
o
gicAnd
*[3] L
o
g
icOr
8
-51 Quic
k Stop
Sel
ect
See
par
. 8-50 * [3]
Logi
cOr
8
-52 DC B
rake Select
See
par
. 8-50 * [3]
Logi
cOr
8
-53 Start Sel
ect
See
par
. 8-50 * [3]
Logi
cOr
8
-54 R
e
versing Sel
e
ct
See
par
. 8-50 * [3]
Logi
cOr
8
-55 Set-up
Selec
t
See
par
. 8-50 * [3]
Logi
cOr
8
-56
Pr
es
et Re
fer
e
n
ce
Sel
ec
t
See
par
. 8-50 * [3]
Logi
cOr
8-9* Bus
J
o
g / Feedback
8-94 B
u
s f
e
edback 1
0x8000 - 0
x7FFF
* 0
13
-** Controller Logic
13
-0
* Logi
c C
o
n
trolle
r Se
tt
ings
13-00
L
o
gic Con
troller Mo
de
*[0] Off
[1
] On
13-01
St
a
rt Event
[0
] F
a
ls
e
[1
] Tr
ue
[2
] R
u
n
n
in
g
[3
] In
R
a
n
g
e
[4
] O
n
R
e
fe
re
nc
e
[7
] O
u
tO
fCurre
ntRa
ng
e
[8
] B
e
lo
w
ILow
[9
] A
b
ov
eI
H
igh
[1
6]
Th
e
rm
a
lW
ar
ni
n
g
[1
7
] Ma
in
Ou
tO
fR
a
n
ge
[1
8
] R
e
ve
rs
in
g
[1
9
] W
a
rn
in
g
[2
0]
Ala
rm
_
Tr
ip
[2
1]
Al
arm
_
Tr
ip
Lo
ck
[2
2-25] C
o
m
para
tor
0-3
[2
6-29] Lo
gicRu
le0-3
[3
3] Dig
ita
lInp
ut_18
[3
4] Dig
ita
lInp
ut_19
[3
5] Dig
ita
lInp
ut_27
[3
6] Dig
ita
lInp
ut_29
[3
8] Dig
ita
lInp
ut_33
*[39] Star
tCom
m
a
n
d
[4
0] Dr
iv
eS
topp
ed
13-02
St
o
p
Event
See par. 13-01 * [40]
Dr
iveS
topp
ed
13-03
Reset Logic Con
tro
ller
*[0] Do
not
reset
[1
] R
e
se
t
Lo
gic
C
o
n
tr
o
ller
13
-1
* C
o
m
p
ar
at
o
rs
AF-60 LP™ Micro Drive Programming Guide
65
5