Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.
Parameter
Device
Symbol
Min
Max
Unit
Input Voltage
All
V
IN
-0.3 36 Vdc
Continuous
Operating Ambient Temperature
All
T
A
-40 85 °C
(see
Thermal
Considerations
section)
Storage Temperature
All
T
stg
-55 125 °C
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
AXB030
V
IN
18.0
24.0
30.0
Vdc
AXB050
V
IN
20.0
24.0
32.0
Vdc
Maximum Input Current
All
I
IN,max
3.5
Adc
(V
IN
= 20V, V
O
= 12V,
I
O
=I
O, max
)
Input No Load Current
V
o
= 3.3
Vdc
I
IN,No Load
60 mAdc
(V
IN
= 24Vdc, Io = 0, module enabled)
V
o
= 12
Vdc
I
IN,No Load
110 mAdc
Input Stand-by Current
V
o
= 3.3
Vdc
I
IN,stand-by
3
mA
(V
IN
= 24Vdc, module disabled)
V
o
= 12
Vdc
I
IN,stand-by
3
mA
Inrush Transient
All
I
2
t
1
A
2
s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V
IN
=20V
to 30V, I
O
= I
Omax
; See Figure 25)
All
50
mAp-p
Input Ripple Rejection (120Hz)
All
50
dB
CAUTION: These power modules can be used in a wide variety of applications ranging from simple standalone
operation to an integrated part of sophisticated power architectures. To preserve maximum flexibility, no internal fuse
has been provided. Also, extensive safety testing has shown that no external fuse is required to protect the unit.
However, it is still recommended that some type of current-limiting power source be used to protect the module and
evaluated in the end-use equipment.