MECHANICAL CONSIDERATIONS
5. Mechanical considerations
5.1. LED module dimensions
This schematic drawing contains further details on the
dimensions of available PrevaLED
®
Core Z2 LED modules.
For 3D fi les, LES and OCA categories, see the datasheet
at:
www.osram.com/prevaled-core
. These 3D fi les in differ-
ent formats may be used for the construction of luminaires.
5.2. Mechanical protection of the LED module
The pressure-sensitive LES (light-emitting surface) of the
LED module is protected against mechanical infl uence by
a protective foil. The LED module must not be switched
on if the protective foil is still in place because it could
be destroyed. Please do not apply pressure on the LES,
neither before nor after installation and removal of the
protective foil.
For operation in damp, wet or dusty environments, the
user has to make sure that an adequate ingress protection
and the protection of the LED module and the ECG is
warranted by means of a suitable IP classifi cation of the
luminaire housing (in due consideration of the luminaire
standard IEC 60598-1, irrespective of the different require-
ments in indoor and outdoor areas).
LES: Light-emitting surface
OCA (Optical contact area): Attachment and reference
surface for optics (e.g. refl ectors, lenses)
kg
All fi gures in mm