beautypg.com

Cleaning the strainer in the water drain lug – Factory Direct Hardware Toto ABA990X#01FCP User Manual

Page 38

background image

38

Cleaning the strainer in the water drain lug

Debris in the plumbing will collect in the strainer, so after connecting the plumbing and running water through it and after
the trial operations, please be sure to clean the strainer.

Caution

If the product won't be delivered to the customer for a long time or if it will not be used for a
long time, please remove the water from the function module and shut off the power. (See
Instruction Manual.)

After the water has run out of the fill-tub outlet, the water inside the function module will still be quite hot. Please wait
until the equipment cools to avoid scalds or burns.

Hot and cold water will run out of the water drain lug, so please place a bucket or other container underneath the
function module to catch the water.

Close the hot/cold water valves in the plumbing connected to the connection ports.

The location of the shut-off valves will vary with the installation site.

Hot water

connection

Hot water valve

Cold water valve

Cold water

connection

Close

Close

Set the on the controller to ON and wait around 20 seconds.

Please do this with the On/Off button set to ON.

After confirming that no water is flowing out of the fill-tub outlet, turn the On/Off button to OFF.

• If the water continues flowing, please set the On/Off button to OFF again and start from step (1).

Sometimes, the controller will display error code 572.

• This is a notice that the water has been shut off. After resetting the error (See Page 37), set the On/Off

button to OFF and proceed to step (4).