beautypg.com

When an error code is displayed, 6) purge operation, Handling problems – Factory Direct Hardware Toto ABA990X#01FCP User Manual

Page 36

background image

36

(6) Purge operation

Remove the drain plug in the bathtub and empty the bathtub.

Set the On/Off button on the controller to OFF.

Set to ON.

Please remove the drain plug in the bathtub so that the water in the bathtub will all run out.
The purge operation will end automatically after approximately two minutes.

When an error code is displayed

Error Code

Cause

Response

032

Drain valve open

Is the bathtub drain valve closed?

079

No hot water

Is sufficient hot water available from the water heater?

• Please check the temperature setting/operation of the water heater.

152

Incoming water temperature
problem

Is hot water being supplied to the cold water connection port of
the function module?

• Please check the connections of the plumbing to the function

module.

262

Water level sensor open circuit

Is the water sensor cable connected?

Is there a break in the water sensor cable?

572

No water

Is the water main/shut-off valve turned on?

C04

Shoulder warming pump rpm
problem

Is there enough hot water in the bathtub?

Is debris blocking the intake port?

Is the intake port blocked?

Other

---

Please try again after resetting the error.

Handling problems