beautypg.com

Rf12, Ac characteristics (pll parameters) – Rainbow Electronics RF12 User Manual

Page 9

background image

RF12

Tel: +86-755-86096587 Fax: +86-755-86096602 E-mail: [email protected] http://www.hoperf.com

I

dd_RX

Supply current (RX mode)

315/433 MHz bands

868 MHz band

915 MHz band

11

12

13

13

14

15

mA

I

pd

Standby current (Sleep

mode)

All blocks disabled

0.3

µA

I

lb

Low battery voltage

detector current

consumption

0.5

µA

I

wt

Wake-up timer current

consumption

1.5

µA

I

x

Idle current

Crystal oscillator and

baseband parts are on

3

3.5

mA

V

lb

Low battery detect

threshold

Programmable in 0.1 V

steps

2.2

5.3

V

V

lba

Low battery detection

accuracy

±75

mV

V

il

Digital input low level

voltage

0.3*V

dd

V

V

ih

Digital input high level

voltage

0.7*V

dd

V

I

il

Digital input current

V

il

= 0 V

-1

1

µA

I

ih

Digital input current

V

ih

= V

dd

, V

dd

= 5.4 V

-1

1

µA

V

ol

Digital output low level

I

ol

= 2 mA

0.4

V

V

oh

Digital output high level

I

oh

= -2 mA

V

dd

-0.4

V

AC Characteristics (PLL parameters)

Symbol Parameter

Conditions/Notes

Min

Typ

Max

Units

f

ref

PLL reference

frequency

(Note 1)

8

10

12

MHz

f

o

Receiver LO /

Transmitter carrier

frequency

315MHz band,2.5kHz resolution

433MHz band,2.5kHz resolution

868MHz band,5.0kHz resolution

915MHz band,7.5kHz resolution

310.24

430.24

860.48

900.72

319.75

439.75

879.51

929.27

MHz

t

lock

PLL lock time

Frequency error < 1kHz after

10MHz step

20 us

t

st, P

PLL startup time

With a running crystal oscillator

250

us