Rf12 – Rainbow Electronics RF12 User Manual
Page 23
RF12
1 0 0
2.5
1 0 1
3.33
1 1 0
5
1 1 1
10
The low battery detector and the clock output can be enabled or disabled by bits eb and dc, respectively,
using the Power Management Command.
15. Status Read Command
The read command starts with a zero, whereas all other control commands start with a one. If a read
command is identified, the status bits will be clocked out on the SDO pin as follows:
Status Register Read Sequence with FIFO Read Example:
RGIT
TX register is ready to receive the next byte (Can be cleared by Transmitter
Register Write Command )
FFIT
The number of data bits in the RX FIFO has reached the pre-programmed limit (Can
be cleared by any of the FIFO read methods)
POR
Power-on reset (Cleared after Status Read Command )
RGUR
TX register under run, register over write (Cleared after Status Read Command )
FFOV
RX FIFO overflow (Cleared after Status Read Command )
WKUP
Wake-up timer overflow (Cleared after Status Read Command )
EXT
Logic level on interrupt pin (pin 16) changed to low (Cleared after Status Read
Command )
LBD
Low battery detect, the power supply voltage is below the pre-programmed limit
FFEM
FIFO is empty
ATS
Antenna tuning circuit detected strong enough RF signal
RSSI
The strength of the incoming signal is above the pre-programmed limit
DQD
Data quality detector output
CRL
Clock recovery locked
ATGL
Toggling in each AFC cycle
OFFS(6)
MSB of the measured frequency offset (sign of the offset value)
OFFS(3)-OFFS(0)
Offset value to be added to the value of the frequency control parameter (Four LSB
bits)