beautypg.com

Chapter 7: roof assembly – Grain Systems Tanks PNEG-4135A User Manual

Page 74

background image

Chapter 7: Roof Assembly

sheet and three-post sidewall sheets will have three inside stiffeners per sheet. The inside stiffeners are
only located at the eave bracket locations in the sidewall sheet.

What You Should Know

NOTE: Do not tighten the nuts (C) until all hardware has been installed attaching the inside stiffener (CTS–

2069XX) to the sidewall and the outside stiffener. Bins with an odd number of rings will use the
one-ring outside stiffener (CTS-2071XX), and bins with an even number of rings will use the two-
ring outside stiffener (CTS-2111XX or CTS-2116XX).

1. From the inside perimeter of the sidewall, place the bolt (B) through the hole located approximately 4

in. down from the top of the sidewall sheet (A).

NOTE: Install the bolts from the inside to the outside of the bin, passing through the inside stiffener,

corrugation spacer, sealing washer, sidewall sheet, and outside stiffener and flange nut.

2. On the inside perimeter, install a sealing washer (F), corrugation spacer (E), and inside stiffener (D).

3. Install a flange nut (C) to the bolt (B) and repeat this process with the remaining hardware. Tighten

hardware to the recommended torque specifications, see

Bolt Torque Specifications, page 26

.

Figure 7-1 Inside stiffener to the one-ring top stiffener for bins with an odd number of rings

A

Sidewall

E

Corrugation spacer (S-7041)

B

3/8 x 1-1/2 in. flange bolt (S-7488)

F

Sealing washer (S-3558)

C

3/8 in. flange nut (S-9426)

G

One-ring top stiffener (CTS-2071XX)

D

Inside stiffener (CTS-2069XX)

H

Assembled view

74

Pneg-4135A 135 Ft Diameter 40-Series Bin