Bolt torque specifications, Chapter 3: hardware requirements – Grain Systems Tanks PNEG-4135A User Manual
Page 26
Chapter 3: Hardware Requirements
Table 3-1 Hardware for 3-Post Sidewall Sheets on Bins that are 135 Ft in Diameter (cont'd.)
Gauge
Horizontal Seam
Vertical Seam
Stiffener to Sidewall
Overlap Seam
11L
3/8-1.5 (22)
3/8-1.5 (48)
3/8-1.5 (12)
3/8-1.5 (2)
10L
3/8-1.5 (22)
3/8-1.5 (48)
3/8-1.5 (12)
3/8-1.5 (2)
9L
3/8-1.5 (24)
7/16-2.5 (48)
3/8-1.5 (24)
3/8-2 (6)
8L
3/8-1.5 (24)
7/16-2.5 (48)
3/8-1.5 (24)
3/8-2 (6)
6LF
7/16-2 (20)
7/16-2.5 (72)
3/8-2 (24)
7/16-2 (10)
Bolt Torque Specifications
The specification torque table below will help the installer determine how tight a specific bolt must be. A
bolt that has been over tightened can be just as dangerous as one that hasn't been tightened enough.
IMPORTANT: Bolts should not be tightened in excess of the torque specifications chart listed below.
Bolt
Minimum Torque
Maximum Torque
Sealing Joints
(joints with seal-
ing washers)
Structural Joints
(joints without
any sealing
washers)
Sealing Joints
(joints with seal-
ing washers)
Structural Joints
(joints without
any sealing
washers)
ft-lb
N-m
ft-lb
N-m
ft-lb
N-m
ft-lb
N-m
5/16-18 JS Gr 8 with seal
20
27
—
—
25
34
—
—
3/8 -16 JS Gr 8 with seal
30
41
—
—
35
47
—
—
7/16-14 JS Gr 8 with seal
50
68
—
—
60
81
—
—
3/8–16 YDP Gr 8 flanged
—
—
40
54
—
—
45
61
7/16–14 YDP Gr 8 flanged
—
—
65
88
—
—
75
101
1/2-13 YDP Gr 8 flanged
—
—
100
135
—
—
115
155
26
Pneg-4135A 135 Ft Diameter 40-Series Bin