1. Position the roof panels (K) spanned by the roof exhauster mounting plate on the ground. Align the
roof panel holes as if they are installed on the bin.
2. Temporarily install the roof exhauster mounting plate (F) to the roof panels (K) using bolts (G) and
nuts (E), ensuring all holes are aligned and the teeth of the roof exhauster mounting plate (F) are nes-
tled in between two roof ribs. Also field drill all required holes (H) on the roof panels (K).
3. Using the roof exhauster mounting plate (F), mark or scribe the hole (I) to be cut.
Tip
If tabs are already bent, flip the mounting plate upside down to scribe the hole location.
Figure 8-6 Using the roof exhauster flashing and mounting plate as a template
E
5/16 in. flange nut (S-3611)
K
Roof panel
F
Exhauster mounting plate
I
Marked or scribed hole to be cut
G
5/16 x 1 in hex bolt (S-10260)
J
Field bent inside tab on roof exhauster mounting
plate
H
Holes to be field drilled
4. Bend the tabs (J) downward approximately 90 degrees on the roof exhauster mounting plate (F) to
conform with the roof panel.
NOTE: Bend the tabs on the ground and adjust as necessary once on the roof.