beautypg.com

Installing the roof flashing – Grain Systems Tanks PNEG-4135A User Manual

Page 141

background image

Chapter 7: Roof Assembly

C

Roof panel holes (drilled through rafter)

G

Roof panel holes (drilled through rafter clip)

D

Purlin

Installing the Roof Flashing

The roof flashing will seal the area between the center collar and the roof panels.

What You Should Know
Each roof flashing section overlaps and bolts together with the previously installed roof flashing section.

1. Install the first roof flashing section (A) onto the roof panel, and align the holes on the roof flashing

with the roof panel.

2. Install flange bolts (B) and flange nuts (C), securing the first roof flashing section (A) to the roof panel

ribs.

NOTE: Only the first roof flashing section is installed using only six of the required flange bolts and

nuts. Any remaining unfilled holes will be filled when the last roof flashing section is installed.

Figure 7-50 Installation of the first roof flashing section

3. Place a strip of rope caulk (D) along the edge of the installed roof flashing (A) where the next roof

flashing will overlap.

4. Align the holes along the edge of the next roof flashing (A) with the previously installed roof flashing

holes.

5. Install flange bolts (B) and flange nuts (C), securing the two roof flashing sections (A) together.

Pneg-4135A 135 Ft Diameter 40-Series Bin

141