beautypg.com

Assembling the auto roof vent – Grain Systems Tanks PNEG-4135A User Manual

Page 160

background image

Chapter 8: Accessories

Figure 8-10 Sealing caulk location

D

Roof exhauster assembly

H

Sealing caulk

Assembling the Auto Roof Vent

The following instructions are for assembling the auto-vent. First, check the packing list to ensure all com-
ponents have been shipped. The unit is easiest assembled in the upside-down position as shown in the
instructions.

1. Take all parts out of the shipping box and ensure all parts are present.

2. Turn the roof vent housing assembly (D) upside down.

3. Install a hex bolt(B) through the hole on the side of roof vent housing (D). Install a flange nut (E) to

the hex bolt (B) and tighten.

4. With the curvature facing upward, install the flap assembly (F) into the roof vent housing (D), and

onto the end of the hex bolt (B).

5. Insert another hex bolt (B) through the other side of the roof vent housing (D), and install a flange nut

(E) to the hex bolt (B), between the tab of the flap assembly (F) and the side of roof vent housing (D).

6. Apply a strip of caulking around the three housing sides of the roof vent assembly (D) where it meets

the hold-down angle (A).

7. Place the hold-down angle (A) onto the assembled roof vent assembly (D), with the wide end or long

end of the hold-down angle (A) facing the vent discharge and the short end facing the rear of the
vent.

8. When the hold-down angle (A) is aligned, install #10 self-drilling screws through the roof housing and

into the hold-down angle (A).

160

Pneg-4135A 135 Ft Diameter 40-Series Bin