beautypg.com

Sidedraw instructions, Accessory instructions – Grain Systems Tanks PNEG-1000 User Manual

Page 84

background image

13. Accessory Instructions

84

PNEG-1000 2.66" Commercial Tank Stiffener and Sidewall

Sidedraw Instructions

2.66'' Sidedraw Instructions - 2 Post (Viewed from Inside of Bin)

Wind Ring Installation

Tanks that use wind rings require 2-3/4" diameter holes passing through the sidedraw chute; with the
center no less than 6" from either end and 4-3/8" from the sidewall. The wind ring must penetrate through
the chute and form a complete ring. Do not locate wind ring in 8" space at chute entrance. Field drill
stiffeners for wind ring attachment brackets (if required).

Discharge Tube Installation

1. Use the bottom two (2) holes in the last chute to locate discharge tube 28" below the 7

th

horizontal seam. Refer to

Figure 13A on Page 85

and

Figure 13E on Page 89

for sidewall sheet

hole dimensions.

2. For proper water shed, install plate so upper body sheet overlaps the plate, as shown in

Figure 13D

on Page 88

and

Figure 13F on Page 90

.

3. Use discharge tube assembly as a template, drill all holes 7/16" diameter.

4. Use two (2) beads of caulking to seal discharge plate to body sheets. Use 3/8" bolts and nuts

provided to bolt discharge assembly to body sheets.

Number of Rings in Tank

Chute Location Horizontal Starting Location

All

1. Locate 1

st

chute in 2

nd

ring from top.

2. Top bolt holes in chute to be located on 2

nd

corrugation of body sheet.

11, 12, 15, 17, 19, 21 and 23

3. Center chute over vertical seam.

10, 12, 14, 16, 18, 20, 22 and 24

4. Center chute 56-1/4'' from the 1

st

horizontal seam bolt in the 2

nd

ring.