10. Stiffener Assembly (Inside Only)

52

PNEG-1000 2.66" Commercial Tank Stiffener and Sidewall

3 Stiffeners per Sidewall Sheet

Commercial Stiffener Starting Location - 36' Diameter and Smaller
2.66'' Corrugation Inside Stiffener Only

NOTE: Certain tanks may be stiffened to the eave. Refer to the tank gauge layout sheet

to determine if

this is the case for the bin.

For sidewall to stiffener connections, use 3/8" x 1" bin bolts except on horizontal seam. Stiffener will
bolt every 8".

NOTE: Splice plate and laminated stiffener to sidewall connections use 3/8" x 1-1/2" bin bolts.

Offset joints and 8 gauge splice plated joints use 3/8" x 1" hex flanged head bolts. All other stiffener joints
use 3/8" x 1-1/2" hex flanged head bolts. Flanged nuts are used on the nut side of all stiffened joint
connections.

(See Figure 10B.)

Figure 10B

Ref #

Description

Ref #

Description

A

Horizontal Seam

D

Odd Ring Bins

B

1 Ring Offset Stiffener (SS-7064)

E

Even Ring Bins

C

2 Ring Offset Stiffener (SS-7065 or SS-6982)