INTRODUCTION
The Badger
®
Data Industrial
®
Series 3000 Flow Monitor
is an economical, full featured, digital flow monitor.
The two line x 16 character alphanumeric display can be
configured by the user to display flow rate and flow total.
The panel meter has a NEMA 4X rated front panel and
conforms to DIN Standard dimensions, 96 mm X 96 mm,
for meter sizes and panel cutouts. An optional NEMA 4
wall mount is also available.
The Series 3000 accepts pulse, sine wave, or linear
analog input signals. Like all Data Industrial flow moni-
tors, the Series 3000 may be field calibrated by the user.
For Data Industrial sensors “K” and “offset” numbers are
entered, while other pulse or frequency output sensors
may use a “K” factor only. Analog inputs are fully pro-
grammable for slope and intercept.
Programming is menu driven. All data is entered using
the LCD/keypad interface. A password gate is included
to prevent unauthorized access to programming pa-
rameters. Programming flexibility is extended to units of
measure. In addition to several factory units of measure,
the Series 3000 software permits the custom units for
rate and total to be created by the installer.
The Series 3000 provides one Form C solid-state relay,
and one solid-state switch output. Both are fully program-
mable as either Pulse/Volume, or Set-point control. For
pulse output, the installer can program both the resolu-
tion, and the pulse width. Set-Point control is extremely
versatile with fully independent set and release points
each with its own time delay.
Options available:
• Analog output
• Analog input
• Single Flow channel Input
• One control relay output
• One programmable pulse output
• Low voltage AC/DC supply
• USB
• RS485 w\BACnet or Modbus protocols
• Wall mounting
3000 Series Ordering Matrix
Example: 3000 - x x
Series
Flow Monitor
3000 -
Portable Battery
Operated Kit
3020
Outputs
No Option
0
Analog Output, plus RS485 with
BACnet and Modbus, and USB
1
Mounting
Panel Mount, NEMA 4x Front Panel
0
Wall Mount, NEMA 4x
1
INSTALLATION
Mechanical Installation:
The Series 3000 can be either panel mounted or wall
mounted.
Location:
In any mounting arrangement the primary concern is
easy viewing, and convenient operation of the keypad.
The unit generates very little heat, so no consideration
need be given to cooling or ventilation. However, pro-
longed direct sunlight can damage the front panel so
some level of shading is recommended, especially if
installed in a tropical climate.
Panel Mount Installation
The Model 3000 Panel Mount is designed for through
panel mounting, which allows access to the back of the
unit.
The 3000 is secured to the panel by two draw brackets
shown in Figure 1 below.
Refer to Figure 1 for flow monitor and panel cutout di-
mensions.