SETUP MENU

SETUP MENU

SETUP MENU

SETUP MENU

SETUP MENU

RESET

YES/NO

LFT

ON/OFF

OFF

OFF

OFF

OFF

SELECTION, UNITS

g

g

g

g

g, dwt, ct, oz, oz t,
UNIT 1 (grain), t,
UNIT 2 (mommes),
UNIT 3 (custom)

FUNCTIONS

None

None

None

None

None
Percent
Parts Counting
Check Weighing
Animal Weighing
FillGuide

TM

High Point

SETUP OPTIONS

Statistics

Enable

ON/OFF

OFF

OFF

OFF

OFF

Standard Dev.

pop, sample, OFF

OFF

OFF

OFF

OFF

Mean

ON/OFF

OFF

OFF

OFF

OFF

Sum

ON/OFF

OFF

OFF

OFF

OFF

High

ON/OFF

OFF

OFF

OFF

OFF

Low

ON/OFF

OFF

OFF

OFF

OFF

Difference

ON/OFF

OFF

OFF

OFF

OFF

End, Statistics

Net

ON/OFF

OFF

OFF

OFF

OFF

SETUP OPTIONS (Cont.)

Fill Options

Ref.

Weight, #

Target

To ref

To ref

To ref

To ref

To ref, to zero

End, Fill Options

End, Setup Options

TIME

Set

Enter #

Type

US

US

US

US

US, Euro

Adjust
End, Time

DATE

Set

Enter #

Type

US

US

US

US

US, Euro

End, Date

LOCKSWITCH

Cal

YES/NO

NO

NO

NO

NO

User

YES/NO

NO

NO

NO

NO

Setup

YES

YES

YES

YES

YES/NO

Print

YES/NO

NO

NO

NO

NO

End, Locksw

LIST

END, Setup

SETUP MENU

SETUP MENU

SETUP MENU

SETUP MENU

SETUP MENU

The Setup menu is used to customize the operation of the balance for your specific
requirements. It contains submenus which enable you to turn features on or off, and
program balance parameters.

Reset

changes all submenus to original factory default

settings.

Reset

does not appear if menu has been locked out.

LFT

sets the balance

for type approved operation.

SEL

(selection) specifies one of nine weighing units with

a custom unit for specialized applications.

Functions

contains six mutually exclusive

items, only one at a time can be selected for operation. The functions are: Percent,
Parts Counting, Check Weighing, Animal Weighing, FillGuide

TM

or High Point. Several

of these functions have submenus under the Setup Options Menu which permit
various options to be selected and printed.

Setup Options

contains submenus as

follows: Statistics, Net, Custom Units, Good Laboratory Practices, Parts Counting
Error, Check Weighing Options, Animal Weighing Options, Fill Options, Time, Date,
Lock Switch, List and End. The following figure illustrates the sequence in which
submenus appear on the Setup menu. Areas shaded only appear in the menu if the
appropriate function or weighing unit is selected. Items shown in bold type are the
default settings.

SETUP OPTIONS (Cont.)

Custom Units, Unit 3

Factor
Mantissa

Enter #

Exponent

-3, -2, -1, 0

0

0

0

0, 1, 2, 3

LSD

.5, 1

1

1

1

1, 2, 5, 10, 100

Density

none

none

none

none

none, l, ml, fl oz, qt

End

GLP

Time /Date

ON/OFF

OFF

OFF

OFF

OFF

Bal ID

ON/OFF

OFF

OFF

OFF

OFF

ID #

ON/OFF

OFF

OFF

OFF

OFF

Proj. #

ON/OFF

OFF

OFF

OFF

OFF

Cal

ON/OFF

OFF

OFF

OFF

OFF

Name

ON/OFF

OFF

OFF

OFF

OFF

End, GLP1

Parts Counting Error %

.1,. 25, .5, 1, 2.5, 5, OFF

OFF

OFF

OFF

OFF

Check Weighing Opts.

Reference.

Ref. Weight, #

Display.

norm

norm

norm

norm

norm, none, sign

End, CW Options

Animal Weighing Options

AW0, AW1

AW1

AW1

AW1

AW1, AW2, AW3

MENUS