beautypg.com

Dimensions – M&C TechGroup FT-...-H2 Data sheet User Manual

Page 2

background image

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany

[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

7.4

Technical specifications and illustrations are without

obligation, subject to modifications. 10.96/11.06

Technical Data

Differential pressure in mbar with clean filter elements

air flow in l/hr at 20 °C

D

iff

er

en

tia

l p

re

ss

ur

e

m

ba

r

0

50

100

150

200

250

300

350

400

450

500

FT-3SS-H2

FT-3G-H2

FT-0,1GF-H2

0

10

20

30

40

50

60

Dimensions

PG 13,5

VA

TYP.

NR.

VOLT

Ø 6,5

75

Reset

0-180°C

'L

8

7

6

4 5

N

12 3

L

280

300

350

330

Tu<-30°C

Tref.

Power

230V,50Hz

(115V,60Hz)

Alarm contact

Temperature min.

To>+30°C

58

135

Dimensions in mm

Filter series FT

®

FT-3G-H2

FT-3SS-H2

FT-0,1GF-H2

Option 115V version

Part number

01 F 3006

01 F 3008

01 F 3007

01 F 300. -a

Filter finess / material of filter element

3 µm / glass

3 µm / stainless steel

0,1 µm / glassfibre

Max. pressure

4 bar g

Sample temperature max.

180 °C (M&C-Filters to max. 350 °C on request)

Ambient temperature max.

50 °C

Stagnant space

65 cm

3

Filter surface

70 cm

2

Power supply

230/240V 50Hz, 350VA

115V 60Hz

Electrical connection

2,5 mm

2

terminals, 2x PG13 cable glands

Protection classification / electrical standard

IP 44-EN60529 / EN61010, EN 60519-1

Regulation of temperature

thermostat # PT100 as option #

Temperature adjustment

0-180 °C, (180 °C set in the factory)

Temperature alarm contact

Alarm point: ∆T 30 °C at T

SOLL

, contact rating: 250V, 3A*, 0,25A =

Dimension

350 x 300 x 140 mm (w x h x d)

Weight

6 kg

Method of mounting

wall mounting

Sample connections

G1/4" i DIN ISO 228/1

Material of sample contacting parts

PTFE, glass, FPM