M&C TechGroup PMA 100-L Data sheet User Manual
Oxygen analyser series pma, Special features, Application
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
[email protected] • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
13.5
Embracing Challenge
Safe in operation
High accuracy and reliability
Physical measuring principle, linear
measuring ranges
Fast response time
Transducer unit temperature controlled
at +55 °C
Solid 19" metal housing
Large LCD- indicator with background
lighting
Selectable time constant for noise
damping if needed for unstable process
conditions
4 free selectable O
2
measuring ranges,
incl. zero suppression, lowest span 1%
Manual, automatic or remote range
control
User friendly menu control correspond-
ing to NAMUR recommendations
Isolated output signal 0/4-20mA
4 configurable MIN. or MAX. oxygen
level alarms
4 free configurable isolated binary
inputs, for example: alarm confirmation,
measuring range control, autocal. start
Analogue signal memory during adjust-
ing and calibration
Manual / automatic calibration
3 code levels, access to 2 code levels
only with release code
Flow alarm monitoring
4 free configurable potential free relay
contact outputs, for example: oxygen
level alarm
Special Features
Oxygen Analyser Series PMA®
Version PMA 100-L
Microprocessor based,
19”-rack unit or table version
PMA 100-L
Application
Due to the extremely fast response time of the
patented M&C magneto-dynamic measuring
cell with no stagnant volume as well as the
negligible cross sensitivity from other sample
gas components, the M&C oxygen-analyser
PMA 100-L has a wide variety of applications.
The analyser is a suitable and reliable instru-
ment for monitoring oxygen concentrations
in various gas analytical process control appli-
cations including flue gas measurements,
inert gas installations, fermentation processes
and laboratory process control installations.
Description
The M&C oxygen analyser PMA 100-L is a
temperature controlled instrument which has
been designed for continuous measurements
of oxygen concentrations in particle-free and
dry sample gas. The PMA 100-L is a reliable
and easy-to-operate instrument. It is built
into a housing for 19 inch rack mounting /
table version.
The transducer unit maintains a constant
operating temperature of 55 °C.
The programmable measuring ranges are dis-
played on the LCD display. Sample gas con-
nections as well as connectors for incoming
power supply and all output / input signals
are located at the rear side of the analyser. The
sample gas enters the analyser via an external
protective fine-filter. The required flow rate
can be adjusted at the flow meter with needle
valve, mounted on the front panel upstream
the M&C measuring cell and the flow cham-
ber with flow alarm sensor. The internal tub-
ing is made of PTFE and PVDF.
Measuring principle of M&C ox-
ygen analyser
The PMA 100-L utilises the paramagnetic
principle of operation to measure oxygen
concentration. The analyser measures the
paramagnetic susceptibility of the oxygen
in the sample gas by means of the M&C
magneto-dynamic measuring cell. The physi-
cal propertys which distinguishes oxygen
from other gases is its paramagnetism. It is
significantly higher comparing to other com-
mon gases. This operation principle is one of
the most accurate and reliable procedures to
determine the oxygen concentration in a gas
mixture from 0 to 100 Vol.%.
The robust M&C cross-flow cell has no
stagnant volume. Advantages are the fast
response time, the flow rate up to 60 l/hr, the
small volume of 2 ml, the extremely low drift,
the absolute linearity and the negligible cross
sensitivity against other sample gas compo-
nents. With a proper sample conditioning
and pressure, the M&C cell will never need
replacing.