Dimensions

Gas sample dilution system version DIL-U

Part-No.

Type

Dilution gas sample probe SP2000H/DIL-U/P Part No.

SP2000H/DIL-U/P

20S4950(a) *see to dilution ratio

Dilution pump unit, standard DIL-U/A Part No.

DIL-U/A

20S4955(a)

Dilution pump unit, standard DIL-U/A Part No.

DIL-U/N

20S4960(a)

Option: Gas cooler ECP1000G/SR25 Part No.

ECP1000G/SR25

20S4965(a)

Option: bypass DIL-U/B Part No.

DIL-U/B

20S4970(a)

Insitu sample tube or prefilter

optional available, see data sheet 2-1.1b; 2-1.5.1; 2-1.6.1/2; 2-1.9.5

Dilution ratio

1:1 up to 100:1; adjustable via corresponding orifices
* please specify the required dilution ratio with the order

Sample flow rate

from approx. 1 Nl/hr up to 50 Nl/hr

Dilution gas flow rate

from approx. 30 Nl/hr up to 100 Nl/hr

Dilution gas pressure at DIL-U/N

>3 bar g

Material of sample contacting parts

stainless steel 316Ti, 1.4404, glass, FPM, PTFE

Dimensions from dilution pump unit DIL-U

19"-rack, 6U, 84HP, depth = 460 mm

Gas connections

thread G1/4" i

Power supply

230V 50Hz optional 115V 60Hz (a)

Weight

dilution gas sample probe SP2000H/DIL-U/P: 15 kg, dilution pump unit DIL-U: 15 kg

Further technical data see data sheet SP2000, 2-1.1b and 2-1.1.7.

110

260

345

207

340

Sample

8 9

L

4 5

'

7

6

NL

2 3

1

Sample

Gas connections DN4/6

Tsoll

Tu <-30 C

0-180 C

To >+30 C

Test gas

Dilution gas

Low temp. alarm

Power

230V, 50Hz

(115V, 60Hz)

Dilution gas

6HE

45

84TE

360

420

M&C

FPF-0,1

Filter

FM2

Messgas

Sample

FM1

S1

Vakuum Ein

Vacuum On

Bypass1

FM1

On

S2

Test gas

Testgas

Bypass2 Pump

Vakuum

Vacuum

Endgas

Span

Open

Fi1

FM2

Auf

Kondensat/Messgas

Condensate/Sample

P1

Sensor

FA-1,bi

FM1

Kondensat/Bypass1

Condensate/Bypass1

Y1

LA1

P2

Y2

Auf

Zu

Closed

FM4

-0,2

M1

Durchfluss

Flow rate

Verdünnungsgasdruck

Dilution gas pressure

FM5

3,0

4,0

5,0

6,0

M2

Zu/Closed

2,0

1,0

0,0

FM3

-0,8

-1,0

Pressure set

Druckeinstellung

PR1

Beh.Leitung

0,0

DIL-U

Dilution unit

Open

Span

Endgas

Dilution gas

Verdünnungsgas

-0,4

-0,6

Gas connections G1/4"-i

Dimensions in mm

Technical Data