APPENDIX A
GMA 1347 Message Advisories
Alerts Window Message
Comments
GMA1 FAIL – GMA1 is inoperative.
The audio panel self-test has detected a failure. The audio panel is unavailable. The
G1000 system should be serviced.
GMA2 FAIL – GMA2 is inoperative.
GMA XTALK – GMA crosstalk error
has occurred.
An error has occurred in transferring data between the two GMAs. The G1000 system
should be serviced.
GMA1 CONFIG – GMA1 config error.
Config service req’d.
The audio panel configuration settings do not match backup configuration memory.
The G1000 system should be serviced.
GMA2 CONFIG – GMA2 config error.
Config service req’d.
MANIFEST – GMA1 software
mismatch, communication halted.
The audio panel has incorrect software installed. The G1000 system should be serviced.
MANIFEST – GMA2 software
mismatch, communication halted.
GMA1 SERVICE – GMA1 needs
service. Return unit for repair.
The audio panel self-test has detected a problem in the unit. Certain audio functions may
still be available, and the audio panel may still be usable. The G1000 system should be
serviced when possible.
GMA2 SERVICE – GMA2 needs
service. Return unit for repair.
GIA 63W Message Advisories
Alerts Window Message
Comments
GIA1 CONFIG – GIA1 config error.
Config service req’d.
The GIA1 and/or GIA2 configuration settings do not match backup configuration
memory. The G1000 system should be serviced.
GIA2 CONFIG – GIA2 config error.
Config service req’d.
GIA1 CONFIG – GIA1 audio config
error. Config service req’d.
The GIA1 and/or GIA2 have an error in the audio configuration. The G1000 system
should be serviced.
GIA2 CONFIG – GIA2 audio config
error. Config service req’d.
GIA1 COOLING – GIA1 temperature
too low.
The GIA1 and/or GIA2 temperature is too low to operate correctly. Allow units to
warm up to operating temperature.
GIA2 COOLING – GIA2 temperature
too low.
GIA1 COOLING – GIA1 over
temperature.
The GIA1 and/or GIA2 temperature is too high. If problem persists, the G1000 system
should be serviced.
GIA2 COOLING – GIA2 over
temperature.
GIA1 SERVICE – GIA1 needs service.
Return the unit for repair.
The GIA1 and/or GIA2 self-test has detected a problem in the unit. The G1000 system
should be serviced.
GIA2 SERVICE – GIA2 needs service.
Return the unit for repair.