MFD & PFD Message Advisories
Alerts Window Message
Comments
DATA LOST – Pilot stored data was
lost. Recheck settings.
The pilot profile data was lost. System reverts to default pilot profile and settings. The
pilot may reconfigure the MFD & PFDs with preferred settings, if desired.
XTALK ERROR – A flight display
crosstalk error has occurred.
The MFD and PFDs are not communicating with each other. The G1000 system should
be serviced.
PFD1 SERVICE – PFD1 needs service.
Return unit for repair.
The PFD and/or MFD self-test has detected a problem. The G1000 system should be
serviced.
PFD2 SERVICE – PFD2 needs service.
Return unit for repair.
MFD1 SERVICE – MFD1 needs
service. Return unit for repair.
MANIFEST – PFD1 software
mismatch, communication halted.
The PFD and/or MFD has incorrect software installed. The G1000 system should be
serviced.
MANIFEST – PFD2 software
mismatch, communication halted.
MANIFEST – MFD1 software
mismatch, communication halted.
PFD1 CONFIG – PFD1 config error.
Config service req’d.
The PFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.
PFD2 CONFIG – PFD2 config error.
Config service req’d.
MFD1 CONFIG – MFD1 config error.
Config service req’d.
The MFD configuration settings do not match backup configuration memory. The
G1000 system should be serviced.
SW MISMATCH – GDU software
version mismatch. Xtalk is off.
The MFD and PFDs have different software versions installed. The G1000 system
should be serviced.
PFD1 COOLING – PFD1 has poor
cooling. Reducing power usage.
The PFD and/or MFD is overheating and is reducing power consumption by dimming
the display. If problem persists, the G1000 system should be serviced.
PFD2 COOLING – PFD2 has poor
cooling. Reducing power usage.
MFD1 COOLING – MFD1 has poor
cooling. Reducing power usage.
PFD1 KEYSTK – PFD1 [key name] Key
is stuck.
A key is stuck on the PFD and/or MFD bezel. Attempt to free the stuck key by pressing
it several times. The G1000 system should be serviced if the problem persists.
PFD2 KEYSTK – PFD2 [key name] Key
is stuck.
MFD1 KEYSTK – MFD [key name] Key
is stuck.
CNFG MODULE – PFD1 configuration
module is inoperative.
The PFD1 configuration module backup memory has failed. The G1000 system should
be serviced.
PFD1 VOLTAGE – PFD1 has low
voltage. Reducing power usage
The PFD1 voltage is low. The G1000 system should be serviced.