beautypg.com

Connecting to tv, Using with seesnake, Inspection equipment – RIDGID micro CA-300 User Manual

Page 16

background image

micro CA-300 Inspection Camera

14

The copy and delete options are available

from computer operation.

Connecting to TV

The micro CA‑300 Inspection Camera can be

connected to a television or other monitor

for remote viewing or recording through the

included RCA cable.
Open the right side port cover (Figure 3). In‑

sert the RCA cable into the TV‑Out jack. Insert

the other end of the cable into the Video‑In

jack on the television or monitor. Check to

make sure the video format (NTSC or PAL)

output is set properly. The television or

monitor may need to be set to the proper

input to allow viewing.

Using with SeeSnake

®

Inspection

Equipment

The micro CA‑300 Inspection Camera can

also be used with various SeeSnake Inspec‑

tion Equipment and is specifically designed

to be used with the microReel, microDrain™

and the nanoReel Inspection Systems. When

used with these types of equipment, it retains

all of the functionality described in this man‑

ual. The micro CA‑300 Inspection Camera can

also be used with other SeeSnake Inspection

Equipment for viewing and recording only.
For use with SeeSnake Inspection Equip‑

ment, the imager head and any cable exten‑

sions must be removed. For the microReel,

microDrain, nanoReel and similar equip‑

ment, see the operator’s manual for informa‑

tion on proper connection and use. For other

SeeSnake Inspection Equipment (typically a

reel and monitor), an adapter must be used

to connect the micro CA‑300 Inspection

Camer a to a Video‑Out port on the SeeSnake

Inspec tion Equipment. When connected in

this manner, the micro CA‑300 Inspection

Camera will display the camera view and can

be used for recording.
When connecting to SeeSnake Inspection Equip‑

ment (microReel, microDrain™, or nano ‑Reel),

align the interconnect module connected to your

reel with the cable connector onthe micro CA‑300

Inspection Camera, and slide it straight in, seating

it squarely. (See Figure 19.)

Figure 19 - Camera Connector Plug Installed

NOTICE

Do not twist the connector plug to

prevent damage.
Locating the Sonde
If used with a sonde (In‑Line Transmitter),

the sonde can be controlled two ways. If the

reel is equipped with a sonde key, that can

be used to turn the sonde ON and OFF. Oth‑

erwise, the sonde is turned ON by decreas‑

ing LED brightness to zero. Once the Sonde

has been located, the LEDs can be returned

to their normal brightness level to continue

the inspection.
A RIDGID locator such as the SR‑20, SR‑60,

Scout, or NaviTrack® II set to 512 Hz can be

used to locate features in the drain being in‑

spected.

Figure 20 - Locating the Reel Sonde

To locate the Sonde, turn the locator ON and

set it to Sonde mode. Scan in the direction of

the Sonde’s probable location until the loca‑

tor detects the Sonde. Once you have detect‑

ed the Sonde, use the locator indications to

zero in on its location precisely. For detailed

instructions on Sonde locating, consult the

Oper ator’s Manual for the locator model you

are using.