beautypg.com

Xerox 155 User Manual

Page 68

background image

Printer requirements and specifications

6-4

Installation Planning Guide

WYE (or Star)

configurations–

50 Hz

For the 50 Hz WYE configuration, measure the WYE or Star
connection voltages at the power source.

The following lists the 50 Hz WYE/Star printer outlet information
for 380 and 400 volts.

Printer power

outlet/cord voltage

configurations–50

Hz

For 50 Hz systems outlet/power cord configurations, consult your
local service representative to determine the type of plug and
receptacle to use.

Table 6-3. Printer (50 Hz) WYE (Star) 415 voltage

Service outlet
configuration

Measurement
of wiring

Nominal

Range

5 Wire 415 V

Line 1 to line 2

415 V RMS

374-457 V RMS

5 Wire 415 V

Line 2 to line 3

415 V RMS

374-457 V RMS

5 Wire 415 V

Line 1 to Line 3

415 V RMS

374-457 V RMS

5 Wire 415 V

Line 1 to neutral

240 V RMS

216-264 V RMS

5 Wire 415 V

Line 2 to neutral

240 V RMS

216-264 V RMS

5 Wire 415 V

Line 3 to neutral

240 V RMS

216-264 V RMS

Table 6-4. Printer (50 Hz) WYE (Star) 380 and 400 voltage

Service outlet
configuration

Measurement
of wiring

Nominal

Range

5 Wire 380 V

Line 1 to line 2

380 V RMS

342-419 V RMS

5 Wire 380 V

Line 2 to line 3

380 V RMS

342-419 V RMS

5 Wire 380 V

Line 1 to Line 3

380 V RMS

342-419 V RMS

5 Wire 380 V

Line 1 to neutral

220 V RMS

198-242 V RMS

5 Wire 380 V

Line 2 to neutral

220 V RMS

198-242 V RMS

5 Wire 380 V

Line 3 to neutral

220 V RMS

198-242 V RMS

5 Wire 400 V

Line 1 to line 2

400 V RMS

358-438 V RMS

5 Wire 400 V

Line 2 to line 3

400 V RMS

358-438 V RMS

5 Wire 400 V

Line 1 to Line 3

400 V RMS

358-438 V RMS

5 Wire 400 V

Line 1 to neutral

230 V RMS

207-253 V RMS

5 Wire 400 V

Line 2 to neutral

230 V RMS

207-253 V RMS

5 Wire 400 V

Line 3 to neutral

230 V RMS

207-253 V RMS