Xerox 155 User Manual
Page 68
![background image](/manuals/231042/68/background.png)
Printer requirements and specifications
6-4
Installation Planning Guide
WYE (or Star)
configurations–
50 Hz
For the 50 Hz WYE configuration, measure the WYE or Star
connection voltages at the power source.
The following lists the 50 Hz WYE/Star printer outlet information
for 380 and 400 volts.
Printer power
outlet/cord voltage
configurations–50
Hz
For 50 Hz systems outlet/power cord configurations, consult your
local service representative to determine the type of plug and
receptacle to use.
Table 6-3. Printer (50 Hz) WYE (Star) 415 voltage
Service outlet
configuration
Measurement
of wiring
Nominal
Range
5 Wire 415 V
Line 1 to line 2
415 V RMS
374-457 V RMS
5 Wire 415 V
Line 2 to line 3
415 V RMS
374-457 V RMS
5 Wire 415 V
Line 1 to Line 3
415 V RMS
374-457 V RMS
5 Wire 415 V
Line 1 to neutral
240 V RMS
216-264 V RMS
5 Wire 415 V
Line 2 to neutral
240 V RMS
216-264 V RMS
5 Wire 415 V
Line 3 to neutral
240 V RMS
216-264 V RMS
Table 6-4. Printer (50 Hz) WYE (Star) 380 and 400 voltage
Service outlet
configuration
Measurement
of wiring
Nominal
Range
5 Wire 380 V
Line 1 to line 2
380 V RMS
342-419 V RMS
5 Wire 380 V
Line 2 to line 3
380 V RMS
342-419 V RMS
5 Wire 380 V
Line 1 to Line 3
380 V RMS
342-419 V RMS
5 Wire 380 V
Line 1 to neutral
220 V RMS
198-242 V RMS
5 Wire 380 V
Line 2 to neutral
220 V RMS
198-242 V RMS
5 Wire 380 V
Line 3 to neutral
220 V RMS
198-242 V RMS
5 Wire 400 V
Line 1 to line 2
400 V RMS
358-438 V RMS
5 Wire 400 V
Line 2 to line 3
400 V RMS
358-438 V RMS
5 Wire 400 V
Line 1 to Line 3
400 V RMS
358-438 V RMS
5 Wire 400 V
Line 1 to neutral
230 V RMS
207-253 V RMS
5 Wire 400 V
Line 2 to neutral
230 V RMS
207-253 V RMS
5 Wire 400 V
Line 3 to neutral
230 V RMS
207-253 V RMS