beautypg.com

Outlet configurations, 60 hz printer outlet voltages, Outlet configurations -2 – Xerox 155 User Manual

Page 66: 60 hz printer outlet voltages -2

background image

Printer requirements and specifications

6-2

Installation Planning Guide

Outlet configurations

This section discusses specifications for printer outlets and the
required wall outlet configurations for the USA / Canada and
internationally.

NOTE: All power outlets must be dedicated to this equipment.
When determining the electrical connections for your printer,
make sure that:

Each power cord has a separate circuit

The printer power cord configurations match your receptacle

Your electrical outlets are within the required specifications

50 Hz systems: Ensure that power connections are per local
codes/regulations.

60 Hz printer outlet voltages

The following table shows the voltages for the outlets on your
printer. All power outlets must have a dedicated circuit for each
system equipment piece. Make sure each power cord has a
separate circuit.
Table 6-2. Printer (60 Hz) voltage requirements at power

outlet

Service outlet
configuration

Measurement
of wiring

Nominal

Range

4 Wire

Line 1 to neutral

120 V RMS

107-127 V RMS

4 Wire

Line 2 to neutral

120 V RMS

107-127 V RMS

4 Wire

Neutral to
ground

0

0-10 V RMS

4 Wire

Line 1 to line 2

208 V RMS

182-220 V RMS

4 Wire

Line 1 to line 2

240 V RMS

210-254 V RMS