ZF036-060 Bottom Duct Application

ZR060 (5 Ton Belt Drive) Side Duct

Air Flow

(CFM)

Available External Static Pressure - IWG

1

1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

Field Supplied Drive

Standard Drive Option

HIgh Static Drive Option

1200

733

0.44

817

0.52

896

0.60

973

0.68

1047

0.76

1118

0.85

1186

0.94

1252

1.03

1315

1.12

1376

1.22

1400

770

0.52

853

0.60

933

0.67

1010

0.76

1083

0.84

1154

0.93

1222

1.02

1288

1.11

1352

1.20

1413

1.30

1600

811

0.64

895

0.71

974

0.79

1051

0.87

1125

0.96

1196

1.04

1264

1.13

1330

1.23

1393

1.32

1454

1.42

1800

857

0.80

940

0.87

1020

0.95

1097

1.03

1171

1.11

1242

1.20

1310

1.29

1375

1.38

1439

1.48

1500

1.58

2000

907

1.00

990

1.07

1070

1.15

1146

1.23

1220

1.31

1291

1.40

1359

1.49

1425

1.58

1488

1.68

1550

1.77

2200

960

1.24

1043

1.31

1123

1.39

1199

1.47

1273

1.55

1344

1.64

1412

1.73

1478

1.82

1541

1.92

1602

2.01

2400

1015

1.51

1099

1.59

1178

1.66

1255

1.74

1329

1.83

1400

1.92

1468

2.01

1534

2.10

1597

2.19

1658

2.29

2600

1074

1.83

1157

1.90

1237

1.98

1314

2.06

1387

2.14

1458

2.23

-

-

-

-

-

-

-

-

ZR036 - 060 (3-5 Ton Direct Drive) Side Duct

UNIT

TONNAGE

MOTOR

1

SPEED

1. Factory set on medium speed tap.

AVAILABLE EXTERNAL STATIC PRESSURE - IWG

2

2. Includes allowances for a wet evaporator coil, 1” filters, and the heat exchangers. Refer to STATIC RESISTANCES Table for

resistance values.

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

CFM

W

A

TTS

3

3

3. Side Duct application (230 Volts)

HI

1574

320

1530

335

1488

349

1451

363

1411

376

1374

390

1331

403

1292

417

1249

430

MED/HI

1480

263

1433

276

1389

290

1347

303

1303

316

1257

329

1208

343

1153

358

1080

374

MED

1332

208

1286

221

1241

234

1195

246

1146

258

1097

272

1031

288

962

303

919

313

MED/LOW 1227

171

1178

183

1129

195

1076

207

1021

220

953

235

891

248

-

-

-

-

LOW

1075

130

992

134

930

145

858

158

-

-

-

-

-

-

-

-

-

-

4

3

HI

-

-

2067

696

2027

714

1991

734

1953

749

1910

764

1860

769

1770

743

1621

685

MED/HI

1913

539

1877

557

1839

571

1798

585

1764

602

1721

619

1677

638

1621

653

1545

639

MED

1722

408

1682

426

1634

438

1597

455

1554

472

1506

490

1450

505

1404

521

1370

536

MED/LOW 1621

362

1580

380

1532

391

1502

406

1461

423

1411

440

1359

455

1324

469

1278

485

LOW

1332

223

1290

237

1232

247

-

-

-

-

-

-

-

-

-

-

-

-

5

3

HI

2245

883

2247

931

2236

950

2211

964

2171

979

2114

971

2034

940

1948

898

1855

854

MED/HI

2135

771

2116

784

2108

808

2078

826

2041

844

2004

859

1955

861

1886

843

1792

806

MED

2010

637

1989

656

1975

675

1938

696

1900

715

1867

730

1822

740

1784

756

1716

748

MED/LOW 1748

413

1704

432

1669

451

1631

468

1589

479

1551

497

1513

513

1465

523

-

-

LOW

1562

327

1529

339

1491

356

-

-

-

-

-

-

-

-

-

-

-

-

ZF036 (3 Ton Belt Drive) Bottom Duct

Air Flow

(CFM)

Available External Static Pressure - IWG

1

1. Blower performance includes gas heat exchangers and 1” filters. See STATIC RESISTANCE table for additional applications.
2. See RPM SELECTION table to determine desired motor sheave setting and to determine the maximum continuous BHP.
3. kW = BHP x 0.932.

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

Field Supplied Drive

Standard Drive Option

HIgh Static Drive Option

800

613

0.35

724

0.40

826

0.46

920

0.53

1007

0.60

1089

0.67

1165

0.75

1237

0.83

1306

0.91

1372

1.00

1000

640

0.40

751

0.46

853

0.52

947

0.58

1034

0.65

1116

0.73

1192

0.80

1264

0.89

1333

0.97

1399

1.05

1200

669

0.48

779

0.53

881

0.59

975

0.65

1063

0.73

1144

0.80

1220

0.88

1293

0.96

1361

1.04

1427

1.13

1400

702

0.57

812

0.63

914

0.69

1009

0.75

1096

0.82

1177

0.90

1254

0.98

1326

1.06

1394

1.14

1460

1.22

1600

741

0.70

852

0.75

954

0.81

1048

0.88

1135

0.95

1217

1.02

1293

1.10

1365

1.18

1434

1.26

1500

1.35

Field Supplied Drive