115°F
125°F
1250
77
54.7
6.1
22.5
17.8
13.2
-
-
-
50.3
6.7
19.5
15.9
11.3
-
-
-
72
49.8
6.0
30.4
25.8
21.2
16.5
-
-
45.6
6.6
28.3
23.8
19.3
14.7
-
-
67
44.9
5.9
38.3
33.7
29.1
24.5
19.9
-
41.0
6.5
36.3
31.7
27.2
22.7
18.1
-
62
41.4
5.9
41.4
41.4
35.3
30.7
26.1
21.4
38.2
6.5
38.2
38.2
32.7
28.1
23.6
19.0
1500
77
58.2
6.1
25.4
20.1
14.7
-
-
-
53.3
6.7
23.1
17.9
12.6
-
-
-
72
53.0
6.0
34.2
28.9
23.6
18.3
-
-
48.3
6.6
32.0
26.7
21.5
16.3
-
-
67
47.7
5.9
43.0
37.7
32.4
27.1
21.8
-
43.4
6.5
40.8
35.6
30.4
25.2
20.0
-
62
44.0
5.9
44.0
44.0
39.3
34.0
28.7
23.4
40.5
6.5
40.5
40.5
36.5
31.3
26.1
20.8
57
43.5
5.9
43.5
43.5
39.5
34.2
28.9
23.6
40.3
6.5
40.3
40.3
36.1
30.9
25.7
20.5
1750
77
61.6
6.1
28.3
22.3
16.3
-
-
-
56.2
6.7
26.6
19.9
14.0
-
-
-
72
56.1
6.0
38.0
32.0
26.0
20.0
-
-
51.0
6.6
35.6
29.7
23.8
17.9
-
-
67
50.6
5.9
47.7
41.8
35.8
29.8
23.8
-
45.8
6.5
45.4
39.5
33.6
27.7
21.8
-
62
46.6
5.9
46.6
46.6
43.4
37.4
31.4
25.4
42.7
6.5
42.7
42.7
40.4
34.5
28.6
22.7
57
46.1
5.9
46.1
46.1
43.6
37.6
31.6
25.6
42.6
6.5
42.6
42.6
40.0
34.1
28.2
22.3
2000
77
65.1
6.1
31.2
24.5
17.8
-
-
-
59.2
6.7
30.2
21.9
15.3
-
-
-
72
59.2
6.0
41.8
35.1
28.4
21.8
-
-
53.7
6.6
39.2
32.6
26.1
19.5
-
-
67
53.4
5.9
52.5
45.8
39.1
32.4
25.7
-
48.2
6.5
48.2
43.4
36.8
30.2
23.6
-
62
49.2
5.9
49.2
49.2
47.4
40.7
34.1
27.4
45.0
6.5
45.0
45.0
44.2
37.6
31.1
24.5
57
48.7
5.9
48.7
48.7
47.6
40.9
34.2
27.6
44.8
6.5
44.8
44.8
43.8
37.2
30.6
24.0
2250
72
60.1
6.0
44.8
37.5
30.1
22.8
-
-
54.3
6.6
42.0
34.8
27.6
20.4
-
-
67
54.2
5.9
53.7
48.8
41.4
34.1
26.7
-
48.7
6.5
48.7
46.2
39.0
31.8
24.6
-
62
50.0
5.9
50.0
50.0
49.1
41.7
34.4
27.0
45.5
6.5
45.5
45.5
45.1
37.9
30.7
23.5
57
49.4
5.9
49.4
49.4
48.9
41.5
34.2
26.8
45.3
6.5
45.3
45.3
44.8
37.6
30.4
23.2
2500
72
61.0
6.0
47.9
39.9
31.8
23.8
-
-
54.9
6.6
44.8
37.0
29.1
21.3
-
-
67
55.0
5.9
55.0
51.8
43.8
35.8
27.7
-
49.3
6.5
49.3
49.0
41.1
33.3
25.5
-
62
50.7
5.9
50.7
50.7
50.7
42.7
34.7
26.7
46.0
6.5
46.0
46.0
46.0
38.1
30.3
22.5
57
50.1
5.9
50.1
50.1
50.1
42.1
34.1
26.1
45.8
6.5
45.8
45.8
45.8
38.0
30.2
22.4
1. These capacities are gross ratings. For net capacity, deduct air blower motor, MBh = 3.415 x kW. Refer to the appropriate Blower
Performance Table for the kW of the supply air blower motor.
2. These ratings include the condenser fan motors (total 1 kW) and the compressor motors but not the supply air blower motor.
ZR060 (5.0 Ton) Cooling (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Total
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F)
Return Dry Bulb (°F)
90
85
80
75
70
65
90
85
80
75
70
65