Powering off
CAUTION:
Switching the machine off may cause loss of data
being processed.
1.
Before turning the power off, make sure that all print jobs have
completely finished and that the
Online
indicator is not lit.
KEY POINT:
Never turn the power off while data is either being
received or when jobs are being printed.
2.
Open the Power Switch cover at the front of the machine and
press the power switch to the [
] Off position.
KEY POINT:
Power off processing is performed internally on
the machine for a while after the power switch is turned off.
Therefore, do not unplug the power cord from the power outlet
immediately after turning the power switch off.
NOTE: Before you turn the power back on after turning it off, first
make sure that the display on the UI has gone out.
When to shut down and restart the entire system
You may need to perform a full system power down / power up of
both the DocuSP Controller and the machine (IOT) if one of the
following situations occur:
•
Loss of communication between the machine and the DocuSP
Controller
•
Power Saver Mode and the DocuSP Controller do not “wake
up” and therefore need to reestablish a connection
•
The user interface shows “wait” (a locked state)
•
No jobs are transmitting
CAUTION:
Make sure to first resolve any declared faults or error
messages on the machine before shutting down the system.
Follow these procedures to restart the entire printing system:
1.
Open the power switch cover on the machine and press the
power switch to the Off position.
KEY POINT:
Power off processing is performed internally on the
machine for a while after the power switch is turned off. Therefore,
do not unplug the power cord from the power outlet immediately
after turning the power switch off.
NOTE: If you turn the power back on after turning it off, first make