Appendix, 6 mmc record strobe < reception, 7 mmc record exit < reception – Yamaha Professional Audio Workstation AW4416 User Manual
Page 469: 8 mmc reset < transmission, Reception, 9 mmc write < reception, 10 mmc locate (target) < transmission
Appendix
— Reference Guide
Appendix–
53
4.13.6 MMC RECORD STROBE
< Reception >
If the AW4416 is operating as the MMC SLAVE and the
device number of the message matches or is 7F, it will begin
recording if stopped, or punch-in if playing.
STATUS
11110000 F0
System Exclusive Message
ID No.
01111111 7F
Real Time System Exclu-
sive
Device ID
0ddddddd dd
Destination (00-7E,
7F:all call)
Command
00000110 06
Machine Control Command
(mcc) sub-id
00000110 06
Record strobe
EOX
11110111 F7
End Of Exclusive
4.13.7 MMC RECORD EXIT
< Reception >
If the AW4416 is operating as the MMC SLAVE and the
device number of the message matches or is 7F, the
AW4416 will punch-out if it had been recording.
STATUS
11110000 F0
System Exclusive Message
ID No.
01111111 7F
Real Time System Exclu-
sive
Device ID
0ddddddd dd
Destination (00-7E,
7F:all call)
Command
00000110 06
Machine Control Command
(mcc) sub-id
00000111 07
Record Exit
EOX
11110111 F7
End Of Exclusive
4.13.8 MMC RESET
< Transmission >
Transmitted with a device number of 7F when song loading
is completed.
< Reception >
If the AW4416 is operating as the MMC SLAVE and the
device number of the message matches or is 7F, internal
MMC-related settings will be reset to the power-on state.
STATUS
11110000 F0
System Exclusive Message
ID No.
01111111 7F
Real Time System Exclu-
sive
Device ID
0ddddddd dd
Destination (00-7E,
7F:all call)
Command
00000110 06
Machine Control Command
(mcc) sub-id
00001101 0D
Reset
EOX
11110111 F7
End Of Exclusive
4.13.9 MMC WRITE
< Reception >
If the AW4416 is operating as the MMC SLAVE and the
device number of the message matches or is 7F, data will be
written to the specified information field.
STATUS
11110000 F0
System Exclusive Message
ID No.
01111111 7F
Real Time System Exclu-
sive
Device ID
0ddddddd dd
Destination (00-7E,
7F:all call)
Command
00000110 06
Machine Control Command
(mcc) sub-id
01000000 40
Write
0ccccccc cc
Byte Count
0nnnnnnn nn
Writeable Information
Field name
0ddddddd dd
Format defined by the
Information Filed name
: :
0nnnnnnn nn
More nn dd... pairs as
required..
EOX
11110111 F7
End Of Exclusive
4.13.9.1 MMC INFORMATION FIELD - TRACK
RECORD READY
< Reception >
If the AW4416 is operating as the MMC SLAVE and the
device number of the message matches, REC SELECT for the
recorder tracks will be switched on/off according to the data
of the standard track bitmap.
01001111 4F
Track Record Ready
(Information Field name)
0nnnnnnn nn
Data Length (0:all track
off, 3:record track on)
0aaaaaaa aa
1-2tr rec track On(Stan-
dard Track Bitmap)
0bbbbbbb bb
3-9tr rec track On
0ccccccc cc
10-16tr rec track On
4.13.10 MMC LOCATE (TARGET)
< Transmission >
This message will be transmitted with a device number of
7F when a locate-related key such as MARK SEARCH/IN/
OUT is pressed, when a FF/REW/shuttle operation is per-
formed, when returning to the auto-punch pre-roll point, or
when repeating.
< Reception >
If the AW4416 is operating as the MMC SLAVE and the
device number of the message matches, the AW4416 will
locate to the time code location specified by the command
data of the message.
STATUS
11110000 F0
System Exclusive Message
ID No.
01111111 7F
Real Time System Exclu-
sive
Device ID
0ddddddd dd
Destination (00-7E,
7F:all call)
Command
00000110 06
Machine Control Command
(mcc) sub-id
01000100 44
Locate
00000110 06
byte count
00000001 01
"target" sub command
0hhhhhhh hh
hour(Standard Time Code)
0mmmmmmm mm
minute
0sssssss ss
second
0fffffff ff
frame
0sssssss ss
sub-frame
EOX
11110111 F7
End Of Exclusive