EQ/ATT/GRP screen

56

— Reference Guide

Library page

Store or recall EQ settings

[Function]

Store EQ settings in the EQ library, or
recall a stored EQ program.

[Key operation]

• [EQ] key → [F2] (Library) key
• Repeatedly press the [EQ] key until the

screen shown at the right appears.

[Mouse operation]

M button → EQ button → Library tab

[Screen functions]

A

SEL CH

This indicates the currently selected channel.

B

EQ graph

This graphically displays the EQ settings.

C

Output meter

This meter shows the post-EQ output level.

D

TITLE EDIT button

Use this to edit the name (library title) of the EQ
program stored in the EQ library. A library name
of up to 16 characters can be input. Move the
cursor to the TITLE EDIT button and press the
[ENTER] key to access the TITLE EDIT popup
window where you can input a name. For
details on inputting characters, refer to Opera-
tion Guide P.60.

Library numbers 1–40 are recall-only preset
memories, and their names cannot be
changed. Numbers in which no EQ program
has been stored are displayed as “No Data!,”
and their title cannot be changed.

E

RECALL button

Recall the currently selected EQ program from
the list.

If you attempt to recall a number in which no
data has been stored, a message of “ERROR
NO DATA TO RECALL” will appear, and the
recall will not occur.

F

STORE button

Store the current EQ settings.

• Library numbers 1–40 are recall-only preset

memories, and cannot be stored. You can
store only in library numbers 41–128.

• When you store, the EQ program that was

previously stored in that number will be
erased.

Tip!

G

LIBRARY No. (library number)

This shows the library number 1–128.

H

LIBRARY TITLE

This shows the names assigned to each library
number.

I

ROM

A write-protect symbol is displayed for recall-
only programs (library numbers 1–40).

1

4

5

6

J

K

7

8

9

3

2