Electrical

Requirements

B-5

Technical Specifications

Electrical Requirements

Environmental Requirements

Power
Requirements

3825

3225/2025

110 V model

88-132 VAC; 50/60 +/-3 Hz

99-122 VAC; 59.4 to 60.6 Hz

220 V model

187-264 VAC; 50 +/-3 Hz

198-242 VAC; 49.5 to 50.5 Hz

Power
Consumption

(full system)

110 V model

1400 W, 12A

1200 W, 10A

220 V model

1400 W, 7A

1150 W, 5A

Noise Level

Idle maximum: 45 dB (A)

Printing maximum:

3825 — 57 dB(A)

3225 — 55 dB(A)

2025 — 55 dB(A)

»

Note: Measured at a height of 1.5

meters and a distance of 1 meter from

all four sides of the printer.

Ozone Density

The printer emits less than 0.1 parts per million
(ppm) of ozone maximum with a 100% duty cycle for
8 hours of continuous operation.

Relative Humidity

Printing: 20-80% RH (non-condensing)

Storage: 15-95% RH (non-condensing)

Temperature Range

Printing: 50

°

to 90

°

F (10

°

to 32

°

C)

Storage: -4

°

to 109

°

F (-20

°

to 43

°

C)