beautypg.com

Xantrex Technology PROsine 2.0 User Manual

Page 54

background image

Installation

3–12

445-0089-01-01

AC Input Connections

Figure 3-4 is a cutaway top view of the PROsine wiring compartment. It shows
one incoming AC cable and its connections to the PROsine wires.

To make the AC input connections:

1. Run 10AWG 2-conductor-plus-ground cable through one of the cable clamps

on the AC end.

2. Strip about two inches of the jacket from the AC cable and separate the three

wires.

3. Connect the incoming black and white (line and neutral) wires to the PROsine

AC input black and white wires.

4. Connect the incoming ground wire to the screw on the chassis marked

.

Use a crimp-on ring terminal if the AC input ground wire is stranded. Solid
wire can be screwed directly under the head of the screw.

Figure 3-4 Incoming AC Cable (Top, cutaway view of wiring compartment)

Cutaway view of
PROsine wiring
compartment as
seen from the top.

wire nuts or crimp

connections (depending

on type of installation)

grounding screw

clamp

for AC cable

AC cable