Adjustable From the Configure Battery Menu
NOTE
Settings below are for Battery Type = Generic Gel.
Battery Size
200Ah
**
Default Battery Temperature
Warm
Battery Type
Generic Gel
**
Battery Temp. Coefficient
–27mV/°C
Bulk Mode Settings:
•
Max Voltage
•
Max Current (%C)
•
Threshold Voltage
•
Threshold Timeout
•
14.2V
•
25%
•
13.8V
•
3min
Absorption Mode Settings:
•
Max Voltage
•
Max Current (%C)
•
Max Timeout
•
Threshold Current (%C)
•
Threshold Timeout
•
14.2V
•
25%
•
8hr
•
1%
•
3min
Overcharge Mode Settings:
•
Max Voltage
•
Max Current (%C)
•
Max Timeout
•
14.2V
•
20%
•
0
Float Mode Settings:
•
Max Voltage
•
Max Current (%C)
•
Max Timeout
•
Threshold Voltage
•
Threshold Timeout
•
13.8V
•
200%
•
21days
•
12.5V
•
15min
Equalize Mode Settings:
•
Max Voltage
•
Max Current (%C)
•
Max Timeout
•
Threshold Voltage
•
Threshold Timeout
•
13.8V
•
200%
•
0
•
0
•
0
Constant Mode Settings:
•
Voltage Setpoint
•
Current Setpoint
•
13.5V
•
100A
Charger Mode
Standalone
Charger Type
3-Step
Charger High Battery V
Warning Offset
1.0V
NOTE
The values opposite the gray bar are set when you select a battery type. If you did
not subsequently change these settings, they do not need to be recorded.
Table 1-1 PROsine Default Values
Item
Default Value