Prosine features, Ac end, Figure 2-1 ac end view (blank panel option) – Xantrex Technology PROsine 2.0 User Manual
Page 32
Product Orientation
2–2
445-0089-01-01
PROsine Features
AC End
Figure 2-1 AC End View (Blank Panel Option)
Feature
Description
1
ON/OFF/REM Switch:
ON: Normal operation according to the way the unit has been configured
via the display panel.
OFF: The inverter and charger are off; shorepower is not passed through to
the loads. The unit draws the lowest battery current possible (less than
2mA).
REM: With the switch in this position, the unit can be turned on and off
remotely. (For details, see “ON/OFF/REMote Control of PROsine
Operation” on page 5–3.)
2
DISPLAY: Jack for the display panel.
3
BATTERY TEMP/REMOTE: Jack for the battery temperature sensor.
Also provides a connection for remote shutdown. See “Step 10: Connecting
the Remote Shutdown” on page 3–24.
4
SYNC: Jack for synchronizing a second PROsine to produce 120/240V
split phase AC. For details, see Chapter 7, “Series Operation”.
5
Removable panel. The blank panel option is shown. For details, see “AC
Panel Options” on page 2–3. The AC wiring compartment is located
behind the panel.
6
Knockouts for AC wiring
7
Mounting flange